NEW HAVEN, CT —
OSHA Inspection: GOODCOPY PRINTING CENTER, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of GOODCOPY PRINTING CENTER, INC. in 110 HAMILTON STREET PO BOX 8088, NEW HAVEN, CT 06538 (NAICS 323111). OSHA activity number 342695087.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GOODCOPY PRINTING CENTER, INC.
- Site address
- 110 HAMILTON STREET PO BOX 8088
- City
- NEW HAVEN
- State
- CT
- ZIP
- 06538
- Mailing
- 110 HAMILTON STREET PO BOX 8088, NEW HAVEN, CT 06538
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323111
- Employees
- 21
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.22 A01
- Issued
- Oct 20, 2017
- Abate by
- Dec 8, 2017
- Penalty
- Initial $2,897 · Current $2,897
General-duty citation text
29 CFR 1910.22(a)(1): (1) All places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition. LAMINATING DEPARTMENT: The flexible cords attached to the AGL laminator were creating a tripping hazard for the employees.
Recent events (2)
- — I (S) $2897
- — Z (S) $2897
1910.132 D02
- Issued
- Oct 20, 2017
- Abate by
- Dec 8, 2017
- Penalty
- Initial $2,897 · Current $2,897
General-duty citation text
29 CFR 1910.132(d)(2): The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment. WORKSHOP: The employer had not verified through a written certification that the workplace hazard assessment for personal protective equipment (PPE) had been performed as complete.
Recent events (2)
- — I (S) $2897
- — Z (S) $2897
1910.132 F01
- Issued
- Oct 20, 2017
- Abate by
- Dec 8, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(f)(1): The employer shall provide training to each employee who is required by this section to use PPE. WORKSHOP: The employer had not provided training to the employees required to wear personal protective equipment (PPE) on the Workplace Hazard Assessment for all types of PPE.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Oct 20, 2017
- Abate by
- Dec 8, 2017
- Penalty
- Initial $3,622 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc. LAMINIATING DEPARTMENT: The rotating blade of the Skil horizontal bandsaw was unguarded.
Recent events (2)
- — I (S) $0
- — Z (S) $3622
1910.307 C
- Issued
- Oct 20, 2017
- Abate by
- Dec 8, 2017
- Penalty
- Initial $3,622 · Current $3,606 Reduced
General-duty citation text
29 CFR 1910.307(c): Electrical installation. Equipment, wiring methods, and installation of equipment in hazardous locations were not intrinsically safe, or approved for the hazardous location, or safe for the hazardous locations: LAMINATING DEPARTMENT: The electrical equipment, such as (but not limited to) the outlets installed and used throughout the work area from where combustible wood dust was generated and accumulated, and the switch installed on Skil bandsaw were neither approved for Class II Division 2 hazardous location nor intrinsically safe.
Recent events (2)
- — I (S) $3606
- — Z (S) $3622
1910.95 K02
- Issued
- Oct 20, 2017
- Abate by
- Dec 8, 2017
- Penalty
- Initial $0 · Current $0
8110
General-duty citation text
29 CFR 1910.95(k)(2): The training program shall be repeated annually for each employee included in the hearing conservation program. Information provided in the training program shall be updated to be consistent with changes in protective equipment and work processes. WORKSHOP: The employer had conducted annual hearing conservation training for each employee required to wear hearing protection .
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 323111)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342695087.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.