WEST BEND, WI —
OSHA Inspection: PREMIER WORKFORCE SOLUTIONS, LLC
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of PREMIER WORKFORCE SOLUTIONS, LLC in 432 EAST WASHINGTON STREET, WEST BEND, WI 53095 (NAICS 561311). OSHA activity number 342695285.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PREMIER WORKFORCE SOLUTIONS, LLC
- Site address
- 432 EAST WASHINGTON STREET
- City
- WEST BEND
- State
- WI
- ZIP
- 53095
- Mailing
- 1652 NORTH MAIN STREET, RACINE, WI 53402
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 561311
- Employees
- 7
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C01
- Issued
- Dec 27, 2017
- Abate by
- Jan 3, 2018
- Penalty
- Initial $8,873 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative. (a) The employer did not develop, document and utilize specific energy control procedures (lockout/tag out program), conduct periodic audits and did not provide adequate training on the energy control procedure to ensure that all required elements of the procedure were understood by employees and that the knowledge and skills required for the safe application, usage and removal of the energy controls were acquired by employees performing servicing such as but not limited to belt and pulley changes on HVAC and changing ceiling lights ballast.
Recent events (2)
- — I (S) $3000
- — Z (S) $8873
1910.332 B02
- Issued
- Dec 27, 2017
- Abate by
- Jan 3, 2018
- Penalty
- Initial $8,873 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.332(b)(2): Employees, who were not qualified persons, were not trained in and familiar with any electrically related safety practices not specifically addressed by 29 CFR 1910.331 through 29 CFR 1910.335, but which were necessary for their safety. (a) Employees who were not qualified persons and covered by 1910.332 (a) were not trained electrical safety practices.