Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: UPPER DARBY SIGN COMPANY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of UPPER DARBY SIGN COMPANY in 251 BOOT ROAD, DOWNINGTOWN, PA 19335 (NAICS 339950). OSHA activity number 342695350.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Upper Darby Sign Company — free Get an email when a new federal OSHA severe-injury report for Upper Darby Sign Company is published. One employer, no account, unsubscribe in one click.
Site address
251 BOOT ROAD
City
DOWNINGTOWN
State
PA
ZIP
19335
Mailing
251 BOOT ROAD, DOWNINGTOWN, PA 19335
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339950
Employees
70
Ownership type
A

2 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 5, 2018
Abate by
Jan 16, 2018
Penalty
Initial $8,873 · Current $5,767 Reduced
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle:    a) Jobsite - The employer did not ensure that a foot operated Accurshear Model 625010 (SN# 2191) had guarding designed so as to prevent amputations when cutting pieces of metal less than 12 inches long. Observed on or about 10 OCT 2017.
Recent events (2)
  • — I (S) $5767.45
  • — Z (S) $8873

1910.305 G01 IV A

Other-than-serious 1 instance 3 exposed
Issued
Jan 5, 2018
Abate by
Jan 18, 2018
Penalty
Initial $3,802 · Current $2,471 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:    a) Jobsite - The employer allowed flexible orange extension cords to be used as permanent wiring running to machines that were installed on a permanent basis. Observed on or about 10 OCT 2017.
Recent events (2)
  • — I (O) $2471.3
  • — Z (S) $3802

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342695350.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.