COLEMAN, TX —
OSHA Inspection: AMERICAN LIGHTING & SIGNALIZATION
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of AMERICAN LIGHTING & SIGNALIZATION in SH183 AND COLORADO ST, COLEMAN, TX 76834 (NAICS 238210). OSHA activity number 342696531.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AMERICAN LIGHTING & SIGNALIZATION
- Site address
- SH183 AND COLORADO ST
- City
- COLEMAN
- State
- TX
- ZIP
- 76834
- Mailing
- 2001 108TH ST., GRAND PRAIRIE, TX 75050
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 10
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.132 F03 III
- Issued
- Jan 8, 2018
- Abate by
- Jan 30, 2018
- Penalty
- Initial $12,934 · Current $0 Reduced
General-duty citation text
29 CFR 1910.132(f)(3)(iii): Inadequacies in an affected employee's knowledge or use of assigned PPE indicated that the employee had not retained the requisite understanding or skill. The employer did not ensure employees used assigned personal protective equipment to protect them from electrical shock.
Recent events (2)
- — I (S) $0
- — Z (S) $12934
1910.333 C02
- Issued
- Jan 8, 2018
- Abate by
- Jan 16, 2018
- Penalty
- Initial $12,934 · Current $7,000 Reduced
General-duty citation text
29 CFR 1910.333(c)(2): "Work on energized equipment." Only qualified persons may work on electric circuit parts or equipment that have not been de-energized under the procedures of paragraph (b) of this section. Such persons were not capable of working safely on energized circuits and were not familiar with the proper use of special precautionary techniques, personal protective equipment, insulating and shielding materials, and insulated tools. The employer did not ensure qualified persons were capable of working safely and used proper precautionary techniques where circuits had not been de-energized exposing them to electrical hazards.
Recent events (2)
- — I (O) $7000
- — Z (S) $12934
More inspections at American Lighting & Signalization
View American Lighting & Signalization's full OSHA safety record →
More inspections in this industry (NAICS 238210)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342696531.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.