SACRAMENTO, CA —
OSHA Inspection: ARMY NATIONAL GUARD
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ARMY NATIONAL GUARD in 8410 OKINAWA STREET., SACRAMENTO, CA 95828 (NAICS 928110). OSHA activity number 342699501.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARMY NATIONAL GUARD
- Site address
- 8410 OKINAWA STREET.
- City
- SACRAMENTO
- State
- CA
- ZIP
- 95828
- Mailing
- 8410 OKINAWA STREET., SACRAMENTO, CA 95828
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 928110
- Employees
- 10000
- Ownership type
- D
Citations
4 citations on file for this inspection.
1910.179 J02 III
- Issued
- Nov 21, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.179(j)(2)(iii): Hooks with deformation or cracks. Visual inspection daily; monthly inspection with a certification record which includes the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier, of the hook inspected. Field Maintenance Shop 22: Monthly crane hook inspection were not performed to evaluate safety hazards pertaining to any potential deformation or cracks in the hook.
Recent events (1)
- — Z (S) $0
1910.253 B04 III
- Issued
- Nov 21, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour. Field Maintenance Shop 22: Oxygen cylinders and flammable acetylene cylinders were placed 12 feet apart.
Recent events (1)
- — Z (S) $0
1910.303 G01
- Issued
- Nov 21, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Space about electric equipment. Sufficient access and working space was not provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment. Field Maintenance Shop 22: The knife switch was blocked by the stored equipment on a cart which inhibited access to the switch in the event of an emergency.
Recent events (1)
- — Z (S) $0
1910.305 G01 IV A
- Issued
- Nov 21, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Employer used a substitute for the fixed wiring of a structure. Field Maintenance Shop 22: An extension cord was used in lieu of permanent wiring to power electricity to a bench grinder (Dayton, Model: 4Z911C).
Recent events (1)
- — Z (S) $0
More inspections at Army National Guard
View Army National Guard's full OSHA safety record →
More inspections in this industry (NAICS 928110)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342699501.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.