Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ARMY NATIONAL GUARD

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ARMY NATIONAL GUARD in 8410 OKINAWA STREET., SACRAMENTO, CA 95828 (NAICS 928110). OSHA activity number 342699501.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Army National Guard — free Get an email when a new federal OSHA severe-injury report for Army National Guard is published. One employer, no account, unsubscribe in one click.
Establishment
ARMY NATIONAL GUARD
Site address
8410 OKINAWA STREET.
City
SACRAMENTO
State
CA
ZIP
95828
Mailing
8410 OKINAWA STREET., SACRAMENTO, CA 95828
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
928110
Employees
10000
Ownership type
D

4 citations on file for this inspection.

1910.179 J02 III

Serious Gravity 5 1 instance 10 exposed
Issued
Nov 21, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.179(j)(2)(iii): Hooks with deformation or cracks. Visual inspection daily; monthly inspection with a certification record which includes the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier, of the hook inspected.   Field Maintenance Shop 22: Monthly crane hook inspection were not performed to evaluate safety hazards pertaining to any potential deformation or cracks in the hook.
Recent events (1)
  • — Z (S) $0

1910.253 B04 III

Serious Gravity 5 1 instance 10 exposed
Issued
Nov 21, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour.  Field Maintenance Shop 22: Oxygen cylinders and flammable acetylene cylinders were placed 12 feet apart.
Recent events (1)
  • — Z (S) $0

1910.303 G01

Serious Gravity 5 1 instance 10 exposed
Issued
Nov 21, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Space about electric equipment. Sufficient access and working space was not provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.  Field Maintenance Shop 22: The knife switch was blocked by the stored equipment on a cart which inhibited access to the switch in the event of an emergency.
Recent events (1)
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 1 1 instance 10 exposed
Issued
Nov 21, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Employer used a substitute for the fixed wiring of a structure.  Field Maintenance Shop 22: An extension cord  was used in lieu of  permanent wiring to power electricity to a bench grinder (Dayton, Model: 4Z911C).
Recent events (1)
  • — Z (S) $0

View Army National Guard's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342699501.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.