On , OSHA opened a planned safety inspection of AD & D ENTERPRISE LLC. in 456 10TH AVE, PATERSON, NJ 07522 (NAICS 236118). OSHA activity number 342700523.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch AD & D Enterprise LLC. — free Get an email when a new federal OSHA severe-injury report for AD & D Enterprise LLC. is published. One employer, no account, unsubscribe in one click.
Site address
456 10TH AVE
City
PATERSON
State
NJ
ZIP
07522
Mailing
45 NORTH 9TH STREET, PATERSON, NJ 07522
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
9
Ownership type
A

5 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 9 exposed
Issued
Dec 11, 2017
Penalty
Initial $3,259 · Current $3,259
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:  a) Exterior front of Building: Employees working without hardhats were exposed to a struck by hazard from siding material while were removing and installing siding, on or about 10/13/2017
Recent events (1)
  • — Z (S) $3259

1926.451 C03

Serious Gravity 10 1 instance 4 exposed
Issued
Dec 11, 2017
Penalty
Initial $3,803 · Current $3,803
29 CFR 1926.451(c)(3): Supported scaffold poles, legs, post, frames, and/or uprights were not plumb and braced to prevent swaying and displacement:   a) Exterior front, and side of Building: The post on the pump jack scaffold was not plumb and securely braced, thus exposing employees to scaffold collapse. The scaffold was set up on a uneven side walk without being plumb or braced, on or about 10/13/2017
Recent events (1)
  • — Z (S) $3803

1926.451 G04 I

Serious Gravity 10 1 instance 2 exposed
Issued
Dec 11, 2017
Penalty
Initial $3,803 · Current $3,803
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms.  a) Exterior Front of Building: Employees engaged in siding work were exposed to a fall hazard, at an elevated height of 14 feet above the ground surface. Employees were working without appropriate fall protection  from a pump jack scaffold without side rails installed, on or about 10/13/2017
Recent events (1)
  • — Z (S) $3803

1926.452 J02

Serious Gravity 10 1 instance 2 exposed
Issued
Dec 11, 2017
Penalty
Initial $3,803 · Current $3,803
29 CFR 1926.452(j)(2): Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled.  a) Exterior Building Front: Employees performing work on a pump jack were exposed to a fall hazard  of approximately 14'. The scaffold's poles were not secured at the bottom, on or about 10/13/2017
Recent events (1)
  • — Z (S) $3803

1926.501 B13

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 11, 2017
Penalty
Initial $3,803 · Current $3,803
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b)   a) Exterior - Roof of Building : Employee engaged in residential siding work was exposed to a 35 feet fall hazard while working from the roof without any type of personal fall arrest system, on or about 10/13/2017
Recent events (1)
  • — Z (S) $3803

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342700523.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.