MATHER, CA —
OSHA Inspection: ARMY NATIONAL GUARD
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ARMY NATIONAL GUARD in 10616 SUPERFORTRESS AVE., MATHER, CA 95655 (NAICS 928110). OSHA activity number 342700911.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ARMY NATIONAL GUARD
- Site address
- 10616 SUPERFORTRESS AVE.
- City
- MATHER
- State
- CA
- ZIP
- 95655
- Mailing
- 9800 GOETHE RD, SACRAMENTO, CA 95827
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 928110
- Employees
- 10000
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A01
- Issued
- Nov 21, 2017
- Abate by
- Jan 10, 2018
- Penalty
- Initial $5,432 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding were not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Field Maintenance Shop: A drill press (General, Model 340) was not provided with a guard to protect the operator and other employees from flying chips and rotating parts.
Recent events (2)
- — I (S) $0
- — Z (S) $5432
1910.303 B02
- Issued
- Nov 21, 2017
- Penalty
- Initial $7,243 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing or labeling. Field Maintenance Shop: An electric lamp (Commercial Electric) was plugged into a power tap/strip in lieu of permanent wiring which exposed employees to electric and fire hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $7243
More inspections at Army National Guard