Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COURTEAUX ELECTRIC, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of COURTEAUX ELECTRIC, INC. in 2904 WEST INTERNATIONAL SPEEDWAY BLVD. DAYS INN, DAYTONA BEACH, FL 32114 (NAICS 238210). OSHA activity number 342703337.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Courteaux Electric, INC. — free Get an email when a new federal OSHA severe-injury report for Courteaux Electric, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2904 WEST INTERNATIONAL SPEEDWAY BLVD. DAYS INN
City
DAYTONA BEACH
State
FL
ZIP
32114
Mailing
85 NORTH YONGE STREET, ORMOND BEACH, FL 32174
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
2
Ownership type
A

2 citations on file for this inspection.

1926.501 B10

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 14, 2017
Penalty
Initial $6,338 · Current $3,803 Reduced
29 CFR 1926.501(b)(10): Each employee engaged in roofing activities on low-slope roofs, with unprotected sides and edges 6 feet (1.8 m) or more above lower levels, was not protected from falling by guardrail systems, safety net systems, personal fall arrest:  a. On or about October 11, 2017, two employees working on the roof were exposed to a twenty feet fall hazard because there was no guardrail system, safety net system, personal fall arrest system or safety monitor system being used.
Recent events (2)
  • — I (S) $3802.8
  • — Z (S) $6338

1926.1053 B01

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 14, 2017
Penalty
Initial $3,802 · Current $2,281 Reduced
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  a. On or about October 11, 2017, stairway 2nd floor, back of building, employees were using a 20 feet extension ladder to gain access and exit from the roof.  The ladder was not extended 3 feet and secured to prevent accidental displacement and employees were exposed to a 10 feet fall hazard.