Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: LAUNDRY WAVE INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of LAUNDRY WAVE INC in 500 LEXINGTON AVE., CLIFTON, NJ 07011 (NAICS 236220). OSHA activity number 342707544.

Watch Laundry Wave INC — free Get an email when a new federal OSHA severe-injury report for Laundry Wave INC is published. One employer, no account, unsubscribe in one click.
Establishment
LAUNDRY WAVE INC
Site address
500 LEXINGTON AVE.
City
CLIFTON
State
NJ
ZIP
07011
Mailing
500 LEXINGTON AVE, CLIFTON, NJ 07011
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.403 B02

Serious Gravity 5 2 instances 2 exposed
Issued
Penalty
Initial $2217.00 · Current $1330.00 Reduced
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification:   a) Laundry Room: Employees engaged in trim work were exposed to electric shock while connecting electric tools to metal boxes fed by BX cables, on or about 10/16/17.  b) Laundry Room: Employees engaged in tile work were exposed to electric shock while operating an electric saw controlled  by a single pole switch mounted on a plastic box, on or about 10/31/17
Recent events (2)
  • — I (S) $1330.2
  • — Z (S) $2217

1926.405 A02 II B

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(a)(2)(ii)(B): Runs of open conductors used as temporary wiring branch circuits were located where the conductors would be subject to physical damage, or the conductors were fastened at intervals exceeding 10 feet:    a) Laundry Room: Employees were exposed to electric shock while working around a live electric branch circuits that were laying on the floor and not protected against damage, on or about 10/16/17.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.403 I02 I

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2772.00 · Current $1663.00 Reduced
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph.  a) Utility Room: Employees were exposed to electric shock while working around a live electric panel that was protected with a piece of cardboard, on or about 10/16/17.
Recent events (2)
  • — I (S) $1663.2
  • — Z (S) $2772

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342707544.