GRAND ISLAND, NY —
OSHA Inspection: COMPU-MAIL, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of COMPU-MAIL, LLC in 3235 GRAND ISLAND BLVD., GRAND ISLAND, NY 14072 (NAICS 511140). OSHA activity number 342710209.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- COMPU-MAIL, LLC
- Site address
- 3235 GRAND ISLAND BLVD.
- City
- GRAND ISLAND
- State
- NY
- ZIP
- 14072
- Mailing
- 3235 GRAND ISLAND BLVD., GRAND ISLAND, NY 14072
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 511140
- Employees
- 120
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.147 C06 I
- Issued
- Jan 18, 2018
- Abate by
- Mar 5, 2018
- Penalty
- Initial $6,652 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) On or about 10/18/17, in the Lettershop, employer did not conduct periodic inspections of the Lockout/Tagout procedures for machines such as, but not limited to: Flowmasters. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — Z (S) $6652
- — I (S) $5000
1910.147 C07 I A
- Issued
- Jan 18, 2018
- Abate by
- Mar 5, 2018
- Penalty
- Initial $6,652 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation. a) On or about 10/18/2017, Throughout the facility, employees that are required to Lockout machines such as, but not limited to, Flowmasters when performing maintenance or servicing activities such as changing, setting up or unjamming, were not trained as authorized employees. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — Z (S) $6652
- — I (S) $0
1910.212 A03 II
- Issued
- Jan 18, 2018
- Abate by
- Mar 5, 2018
- Penalty
- Initial $6,652 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s) a) On or about 10/18/2017, in the Inkjet Area, when employees are operating the Cheshire 7050 employees are exposed to pinch points due to unguarded roller in close proximity to where employees retrieve mail coming off the machine. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — Z (S) $6652
- — I (S) $5000
1910.333 B02
- Issued
- Jan 18, 2018
- Abate by
- Mar 5, 2018
- Penalty
- Initial $8,315 · Current $7,000 Reduced
General-duty citation text
29 CFR 1910.333(b)(2): While an employee was exposed to contact with parts of fixed electric equipment or circuits which were deenergized, the circuits energizing the parts were not locked out or tagged or both in accordance with the requirements of this paragraph (b) of 29 CFR 1910.333(b)(2): a) On or about 10/18/2017, in the Machine Shop , when employees were connecting transformer to electrical panel, the circuit energizing the parts was not locked out, exposing employees to unexpected contact with live electrical parts. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — Z (S) $8315
- — I (S) $7000
1910.303 G01
- Issued
- Jan 18, 2018
- Abate by
- Mar 5, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: a) On or about 10/18/2017, in the Inkjet area, electrical panel did not have sufficient space to permit ready and safe operation and maintenance of electrical panel exposing employees to electrical hazards in case of emergency. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — Z (O) $0
- — I (O) $0
More inspections at Compu-Mail, LLC
View Compu-Mail, LLC's full OSHA safety record →
More inspections in this industry (NAICS 511140)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342710209.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.