COLUMBUS, OH —
OSHA Inspection: MILLWOOD, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of MILLWOOD, INC. in 1886 WILLIAMS RD, COLUMBUS, OH 43207 (NAICS 321920). OSHA activity number 342711728.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MILLWOOD, INC.
- Site address
- 1886 WILLIAMS RD
- City
- COLUMBUS
- State
- OH
- ZIP
- 43207
- Mailing
- 1886 WILLIAMS RD, COLUMBUS, OH 43207
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321920
- Employees
- 97
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 D
- Issued
- Jan 31, 2018
- Abate by
- Jun 15, 2019
- Penalty
- Initial $12,934 · Current $7,760 Reduced
General-duty citation text
29 CFR 1910.147(d): Application of control. The established procedures for the application of energy control (the lockout or tagout procedures) shall cover the following elements and actions and shall be done in the following sequence: (1) Preparation for shutdown, (2) Machine or equipment shutdown, (3) Machine or equipment isolation, (4) Lockout or tagout device application, (5) Stored energy (6) Verification of isolation. a. On or about October 18, 2017, located on Line 1, employees were exposed to machine hazards associated with moving parts and ingoing nip points when they engaged in in removing stuck/jammed pieces of wood in a Lewco live roller conveyor where an associated zone of danger existed. The employer did not ensure that employees implemented energy control application steps prior to allowing them to perform lockout activity.
Recent events (3)
- — F (S) $7760.4
- — C (S) $12934
- — Z (S) $12934
1910.147 F03 I
- Issued
- Jan 31, 2018
- Abate by
- Feb 20, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(f)(3)(i): When servicing and/or maintenance is performed by a crew, craft, department or other group, they shall utilize a procedure which affords the employees a level of protection equivalent to that provided by the implementation of a personal lockout or tagout device. a. On or about October 18, 2017, located on Line 1, 6-10 employees would perform cleaning in and around a Lewco live roller conveyor without a group lockout being performed so that all authorized employees had control over their own safety, thereby exposing the employees to the unexpected startup or release of stored energy of the conveyor.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.219 C04 II
- Issued
- Jan 31, 2018
- Abate by
- Feb 20, 2018
- Penalty
- Initial $8,130 · Current $0 Reduced
General-duty citation text
29 CFR 1910.219(c)(4)(ii): Unused keyways shall be filled up or covered. a. On or about October 18, 2017, located on Line 1, there was a Lewco live roller conveyor, that had a set of rotating shaft keyways approximately 30 inches above the floor that were not guarded or filled, thereby exposing the employees to a caught-in hazard. b. On or about October 18, 2017, located on Line 1, there was a Lewco live roller conveyor, that had a set of rotating shaft keyways approximately 30 inches above the floor that were not guarded or filled, thereby exposing the employees to a caught-in hazard.
Recent events (3)
- — F (S) $0
- — C (S) $8130
- — Z (S) $8130
1910.305 B01 I
- Issued
- Jan 31, 2018
- Abate by
- Jun 15, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter shall be effectively closed. a. On or about October 18, 2017, located on Line 1, the employer did not ensure that the conductors entering a terminal box on a Leeson electrical motor were protected from damage. The conduit surrounding the conductors was damaged which revealed the insulation to the conductors.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at Millwood, INC.
View Millwood, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 321920)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342711728.