LEWISTON, ID —
OSHA Inspection: P. KAY METAL, INC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of P. KAY METAL, INC in 152 SOUTHPORT AVE, LEWISTON, ID 83501 (NAICS 331529). OSHA activity number 342712619.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- P. KAY METAL, INC
- Site address
- 152 SOUTHPORT AVE
- City
- LEWISTON
- State
- ID
- ZIP
- 83501
- Mailing
- 152 SOUTHPORT AVE, LEWISTON, ID 83501
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 331529
- Employees
- 36
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.134 D01 III
- Issued
- Jan 23, 2018
- Abate by
- Feb 16, 2018
- Penalty
- Initial $3,880 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.134(d)(1)(iii): The employer did not identify and evaluate the respiratory hazard(s) in the workplace; including a reasonable estimate of employee exposures to respiratory hazards and identification of the contaminant's chemical state and physical form: (Construction Reference 1926.103) a) P. Kay Metals: On or about October 18, 2017 and at times prior, employees were cutting Insblok-19 ceramic blocks while wearing a North 7700-30M Respirator or a 3M Versaflo TR-300 Powered Air Purifying Respirator. Note: Abatement certification is required for this item.
Recent events (3)
- — F (S) $2000
- — C (S) $3880
- — Z (S) $3880
1910.134 H01 II
- Issued
- Jan 23, 2018
- Abate by
- Feb 16, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(h)(1)(ii): Respirators issued to more than one employee were not cleaned and disinfected before being worn by different individuals: (Construction Reference 1926.103) a) P. Kay Metals: On or about October 18, 2017 and at times prior, employees were cutting Insblok-19 ceramic blocks with a North 7700-30M Respirator. Note: Abatement certification is required for this item.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.134 H02 I
- Issued
- Jan 23, 2018
- Abate by
- Feb 16, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or were not packed or stored to prevent deformation of the facepiece and exhalation valve: (Construction Reference 1926.103) a) P. Kay Metals: On or about October 18, 2017 and at times prior, employees were cutting Insblok-19 ceramic blocks with a North 7700-30M Respirator. Note: Abatement certification is required for this item.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.251 A02 I
- Issued
- Jan 23, 2018
- Abate by
- Feb 16, 2018
- Penalty
- Initial $9,054 · Current $0 Reduced
General-duty citation text
29 CFR 1926.251(a)(2)(i): Employers did not ensure that rigging equipment had permanently affixed and legible identification markings as prescribed by the manufacturer that indicate the recommended safe working load; b) P. Kay Metals Building: On or about October 18, 2017 and at times prior, employees were exposed to crushing hazards while hoisting a 480 lbs. prefabricated crane base plate into position with a homemade choker cable. Note: Abatement certification and documentation is required for item.
Recent events (3)
- — F (S) $0
- — C (S) $9054
- — Z (S) $9054
1926.251 A04
- Issued
- Jan 23, 2018
- Abate by
- Feb 16, 2018
- Penalty
- Initial $9,054 · Current $8,000 Reduced
General-duty citation text
29 CFR 1926.251(a)(4): Special custom design lifting accessories for material handling were not marked to indicate the safe working loads and were not proof tested prior to use to 125 percent of their rated load(s): a) P. Kay Metals Building: On or about October 18, 2017 and at times prior, employees were exposed to crushing hazards while hoisting a 480 lbs. prefabricated crane base plate into position with a homemade choker cable. Note: Abatement certification and documentation is required for this item.
Recent events (3)
- — F (S) $8000
- — C (S) $9054
- — Z (S) $9054
1926.602 C01 I
- Issued
- Jan 23, 2018
- Abate by
- Feb 16, 2018
- Penalty
- Initial $9,054 · Current $8,000 Reduced
General-duty citation text
29 CFR 1926.602(c)(1)(i): The rated capacity of the lift truck was exceeded: a) P. Kay Metals: On or about October 18, 2017 and at times prior, employees were hoisting 78 inch outside diameter kettles with a SkyJack SJ643TH forklift. The SkyJack SJ643TH forklift has a capacity of 6000 lbs. and the 78 in. outside diameter kettles weigh 9300 lbs. b) P. Kay Metals: On or about October 18, 2017 and at times prior, employees were hoisting 108 inch outside diameter kettles with a Komatsu 40 forklift. The Komatsu 40 forklift has a capacity of 9000 lbs. and the 108 inch outside diameter kettles weigh 14800 lbs. Note: Abatement certification and documentation is required for this item.
Recent events (3)
- — F (S) $8000
- — C (S) $9054
- — Z (S) $9054
1926.602 D
- Issued
- Jan 23, 2018
- Abate by
- Feb 16, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.602(d): The employer did not ensure that each employee operating a powered industrial vehicle had been trained and evaluated as required by paragraph 29 CFR 1910.178(l): Note: The requirements applicable to construction work under paragraph (d) of this section are identical to those set forth at paragraph (l) of 29 CFR 1910.178. and as referenced by the note contained in 1926.602(d). a) P. Kay Metals: On or about October 18, 2017 and at times prior, employees were hoisting kettle hoods with a Komatsu 40 forklift. b) P. Kay Metals: On or about October 18, 2017 and at times prior, employees were hoisting kettles with a SkyJack SJ643TH forklift. Note: Abatement certification and documentation is required for this item.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1926.1203 A
- Issued
- Jan 23, 2018
- Abate by
- Feb 16, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1203(a): Before it begins work at a worksite, each employer did not ensure that a competent person identifies all confined spaces in which one or more of the employees it directs may work, and identifies each space that is a permit space, through consideration and evaluation of the elements of that space, including testing as necessary. Each employer did not ensure that a competent person identify all confined spaces and identify each space that was a permit space as required. a) P. Kay Metals: On or about October 18, 2017 and at times prior, employees were entering kettle setting shells to install insulation. Employees are entering the space via a removable ladder. The space is a confined space since it is large enough to bodily enter, not intended for human occupancy, and has limited means of egress. The space is not a permit required confined space. Note: Abatement certification is required for this item.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at P. KAY Metal, INC
View P. KAY Metal, INC's full OSHA safety record →
More inspections in this industry (NAICS 331529)
More inspections in ID
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342712619.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.