ALBION, ME —
OSHA Inspection: NEW ENGLAND RENT TO OWN, LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of NEW ENGLAND RENT TO OWN, LLC in 52 MAIN STREET, ALBION, ME 04910 (NAICS 321992). OSHA activity number 342714672.
Where did this inspection happen?
- Establishment
- NEW ENGLAND RENT TO OWN, LLC
- Site address
- 52 MAIN STREET
- City
- ALBION
- State
- ME
- ZIP
- 04910
- Mailing
- 52 MAIN STREET, ALBION, ME 04910
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321992
- Employees
- 25
- Ownership type
- A
Citations
12 citations on file for this inspection.
5(a)(1)
- Issued
- Nov 15, 2017
- Abate by
- Nov 24, 2017
- Penalty
- Initial $3,622 · Current $1,811 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment in a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were allowed to operate a powered industrial truck without wearing a seatbelt: Front Loading Area - On or about October 18, 2017, the employer did not require the operator of a Caterpillar forklift to wear a seatbelt.
Recent events (2)
- — I (S) $1811
- — Z (S) $3622
1910.28 B11 I
- Issued
- Nov 15, 2017
- Abate by
- Nov 24, 2017
- Penalty
- Initial $2,897 · Current $1,449 Reduced
General-duty citation text
29 CFR 1910.28(b)(11)(i): Each employee exposed to an unprotected side or edge of a stairway landing that was 4 feet (1.2 m) or more above a lower level was not protected by a guardrail or stair rail system: Employees were exposed to fall hazards on the stairs, in the following instances: a) Mezzanine - The lower flight of stairs was missing a guardrail system on the inside portion of the flight. b) Mezzanine - The guard rail system on the lower and upper flights were missing midrails.
Recent events (2)
- — I (S) $1448.5
- — Z (S) $2897
1910.303 B02
- Issued
- Nov 15, 2017
- Abate by
- Nov 24, 2017
- Penalty
- Initial $3,622 · Current $1,811 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: Workshop - The relocatable power strip, containing multiple extension cords and melted plastic, was not used in accordance with the listing and labeling.
Recent events (2)
- — I (S) $1811
- — Z (S) $3622
1910.303 G01 I A
- Issued
- Nov 15, 2017
- Penalty
- Initial $2,173 · Current $1,087 Reduced
General-duty citation text
29 CFR 1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening where they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910: Workshop - The working space in front of the breaker panel was blocked.
Recent events (2)
- — I (S) $1086.5
- — Z (S) $2173
1910.305 A02 IX
- Issued
- Nov 15, 2017
- Abate by
- Nov 28, 2017
- Penalty
- Initial $2,173 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(a)(2)(ix): Lamps for general illumination were not protected from accidental contact or breakage by a suitable fixture or lampholder with a guard: Workshop - Lights throughout the workshop were not protected from damage with a guard or a cage.
Recent events (2)
- — I (S) $0
- — Z (S) $2173
1910.305 G02 III
- Issued
- Nov 15, 2017
- Penalty
- Initial $5,070 · Current $2,535 Reduced
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: Flexible cords were not provided with strain relief, in the following instances. a) Workshop - The 100 foot orange cord at the rear of the building. b) Workshop - The large yellow cord powering a light fixture above the center stack of two by fours.
Recent events (2)
- — I (S) $2535
- — Z (S) $5070
1910.305 G01 IV A
- Issued
- Nov 15, 2017
- Abate by
- Jan 12, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: Flexible cords were used in lieu of permanent wiring, in the following instances: a) Workshop - An orange cord that powered the left compound miter saw. b) Workshop - A thick yellow cord that powered a light near a stack of two by fours. c) Workshop - An orange cord that powered the right compound miter saw. d) Workshop - An orange cord that powered the table saw.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.334 A02 II
- Issued
- Nov 15, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposed an employee to injury and the defective or damaged item was not removed from service: Flexible cords were found to be damaged and were not removed from service, in the following instances: a) Workshop - An orange and grey cord had several cuts and gouges in the outer sheath. b) Workshop - A blue 100 foot cord was damaged and improperly repaired.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.334 A03 I
- Issued
- Nov 15, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(3)(i): A flexible cord used with grounding type equipment did not contain an equipment grounding conductor: Flexible cords were missing grounding pins, in the following instances. a) Workshop - The 100 foot blue flexible cord. b) Workshop - The orange and gray 100 foot flexible cord.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1904.40 A
- Issued
- Nov 15, 2017
- Abate by
- Nov 24, 2017
- Penalty
- Initial $724 · Current $362 Reduced
General-duty citation text
29 CFR 1904.40(a): The OSHA logs of recordable occupational injuries and illnesses required to be kept under part 1904, were not provided to a Representative of the Secretary of Labor within four (4) business hours: Facility - The 2017 OSHA 300 log was not provided when requested on October 24, 2017.
Recent events (2)
- — I (O) $362
- — Z (O) $724
1910.22 B
- Issued
- Nov 15, 2017
- Abate by
- Dec 12, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.22(b): The employer did not ensure that each walking/working surface could support the maximum intended load for that surface. Workshop - The employer did not ensure that the mezzanine could support the load placed upon it.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 E02
- Issued
- Nov 15, 2017
- Abate by
- Nov 24, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(2): Portable fire extinguishers were not visually inspected at least monthly: Workshop - The five pound Kidde Class ABC fire extinguisher, mounted near the table saw, was not inspected at least monthly.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at NEW England Rent TO OWN, LLC
View NEW England Rent TO OWN, LLC's full OSHA safety record →
More inspections in this industry (NAICS 321992)
More inspections in ME
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342714672.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.