NEWINGTON, CT —
OSHA Inspection: DUPLI ENVELOPE & GRAPHICS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DUPLI ENVELOPE & GRAPHICS in 124 FRANCIS AVENUE, NEWINGTON, CT 06111 (NAICS 323111). OSHA activity number 342716800.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DUPLI ENVELOPE & GRAPHICS
- Site address
- 124 FRANCIS AVENUE
- City
- NEWINGTON
- State
- CT
- ZIP
- 06111
- Mailing
- 6761 THOMPSON ROAD, SYRACUSE, NY 13211
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323111
- Employees
- 7
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.212 A01
- Issued
- Nov 27, 2017
- Abate by
- Jan 16, 2018
- Penalty
- Initial $8,149 · Current $4,075 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by in-running nip points and rotating parts: Shop Floor: On, or about, October 20, 2017, guards were not provided over the print rollers on the following Jet Press printing presses: A. Jet Press #6. B. Jet Press #5, serial number 3984. C. Jet Press #3, serial number 3050.
Recent events (2)
- — I (S) $4074.5
- — Z (S) $8149
1910.215 A02
- Issued
- Nov 27, 2017
- Penalty
- Initial $4,155 · Current $2,078 Reduced
General-duty citation text
29 CFR 1910.215(a)(2): Abrasive wheel(s) used on grinding machinery were not provided with safety guard(s) which covered the spindle end, nut, flange projections: Shop Floor: On, or about, October 20, 2017, the Craftsman pedestal off-hand grinder was not provided with a side guard.
Recent events (2)
- — I (S) $2077.5
- — Z (S) $4155
1910.215 A04
- Issued
- Nov 27, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work: Shop Floor: On, or about, October 20, 2017, the Craftsman pedestal off-hand grinder was not provided with a work rest.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.215 B09
- Issued
- Nov 27, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel: Shop Floor: On, or about, October 20, 2017, the Craftsman pedestal off-hand grinder was not provided with a tongue guard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 E03 I
- Issued
- Nov 27, 2017
- Penalty
- Initial $8,149 · Current $4,075 Reduced
General-duty citation text
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): Shop Floor: On, or about, October 20, 2017, the cover that prevented access to the main drive belt was not installed on the press.
Recent events (2)
- — I (S) $4074.5
- — Z (S) $8149
1910.219 F01
- Issued
- Nov 27, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(f)(1): Gear(s) were not guarded by a complete enclosure or by one of the methods specified in 29 CFR 1910.219(f)(1)(ii) and (f)(1)(iii): Shop Floor: On, or about, October 20, 2017, the back cover had not been re-installed on each of the following Jet Presses to cover the drive gears: A. Jet Press #6. B. Jet Press #5, serial number 3984. C. Jet Press #3, serial number 3050.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B02
- Issued
- Nov 27, 2017
- Penalty
- Initial $4,155 · Current $2,078 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: Shop Floor, Jet Press #4: On, or about, October 20, 2017, a relocatable power tap was energized through an extension cord to provide power to the print water tank motors.
Recent events (2)
- — I (S) $2077.5
- — Z (S) $4155
1910.305 G01 IV A
- Issued
- Nov 27, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: Shop Floor: On, or about, October 20, 2017, extension cords were used at the following presses to energize the print water tank motors: A. Jet Press #4. B. Jet Press #1.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 323111)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342716800.