Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RUCH CARBIDE BURS, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of RUCH CARBIDE BURS, INC. in 2750 TERWOOD RD, WILLOW GROVE, PA 19090 (NAICS 333515). OSHA activity number 342721941.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ruch Carbide Burs, INC. — free Get an email when a new federal OSHA severe-injury report for Ruch Carbide Burs, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2750 TERWOOD RD
City
WILLOW GROVE
State
PA
ZIP
19090
Mailing
2750 TERWOOD RD, WILLOW GROVE, PA 19090
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333515
Employees
22
Ownership type
A

3 citations on file for this inspection.

1910.1000 A02

Serious Gravity 10 1 instance 6 exposed
Issued
Feb 26, 2018
Abate by
May 30, 2018
Penalty
Initial $5,174 · Current $3,600 Reduced

Hazardous substances 0720

29 CFR 1910.1000(a)(2): Employee(s) were exposed to an airborne concentration of Cobalt listed in Table Z-1 in excess of the 8 hour Time Weighted Average concentration of 0.1 mg/cubic meter:    a) Hand Grinding Area: An employee, Hand Grinder, while sharpening tungsten carbide burs with a hand grinder, was exposed to cobalt at an 8 hour time-weighted average (TWA) of 0.16 milligrams  cobalt per cubic meter of air. This level is 1.6 times the permissible exposure limit of 0.1 milligrams per cubic meter of air. This exposure occurred over a 435 minute sampling period on December 13, 2017. A zero exposure is assumed for the 45 minutes not sampled.
Recent events (2)
  • — I (S) $3600
  • — Z (S) $5174

1910.1000 E

Serious Gravity 10 1 instance 6 exposed
Issued
Feb 26, 2018
Abate by
May 30, 2018
Penalty
Initial $0 · Current $0

Hazardous substances 0720

29 CFR 1910.1000(e): Feasible administrative or engineering controls were not determined and implemented to achieve compliance with the limits prescribed in 29 CFR 1910.1000(a) through (d):  a) Hand Grinding Area: An employee, Hand Grinder, while sharpening tungsten carbide burs with a hand grinder, was exposed to cobalt at an 8 hour time-weighted average (TWA) of 0.16 milligrams cobalt per cubic meter of air. This level is 1.6 times the permissible exposure limit of 0.milligrams per cubic meter of air. This exposure occurred over a 435 minute sampling period on December 13,2017. A zero exposure is assumed for the 45 minutes not sampled.  The employer did not implement feasible administrative and engineering controls.   Feasible abatement methods include but are not limited to: 1. Redesign of the ventilation to capture more dust during grinding operations. 2. Install a stop in the ventilation system capture hood to increase the dust captured by system.  3. Utilize work practice controls to limit the amount of dust that escapes the ventilation.  ABATEMENT STEPS ARE AS FOLLOW:  STEP 1 - As an interim measure, effective respiratory protection shall be provided to and used by exposed employees until feasible and/or administrative controls can be implemented or whenever such controls fail to reduce employee exposure to within permissible exposure limits.  STEP 2 - A written detailed plan of abatement shall be submitted to the Area Director outlining a schedule for the implementation of engineering and/or administrative measures to control employee exposures to hazardous substances as referenced in this citation. This plan shall include, at a minimum, target dates for the following actions which must be consistent with the dates required by this citation:  1.  Evaluation of engineering control options;  2.  Selection of optimum control method and completion of design;  3.  Procurement, installation and operation of selected control measures;  4.  Testing and acceptance or modification/redesign of controls.  All proposed control measures shall be evaluated for each particular use by a competent industrial hygienist or other technically qualified person.  STEP 3 - Abatement shall have been completed by the implementation of feasible engineering and/or administrative controls upon verification of their effectiveness in achieving compliance.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 A01

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Feb 26, 2018
Abate by
Mar 6, 2018
Penalty
Initial $0 · Current $0

Hazardous substances 0720

29 CFR 1910.134(a)(1): When effective engineering controls were not feasible or while they were being instituted, appropriate respirators were not used pursuant to the requirements of 29 CFR 1910.134:  a) Hand Grinding Area: An employee, Hand Grinder, while sharpening tungsten carbide burs with a hand grinder, was exposed to cobalt at an 8 hour time-weighted average (TWA) of 0.16 milligrams cobalt per cubic meter of air. This level is 1.6 times the permissible exposure limit of 0.1 milligrams per cubic meter of air. This exposure occurred over a 435 minute sampling period on December 13, 2017. A zero exposure is assumed for the 45 minutes not sampled. No respirator was used by the exposed employee.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Ruch Carbide Burs, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342721941.