OSHA Inspection: ANTHONY L. ROBINSON LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ANTHONY L. ROBINSON LLC in 1727 LAFAYETTE AVENUE, SAINT LOUIS, MO 63104 (NAICS 238130). OSHA activity number 342723343.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Anthony L. Robinson LLC — free Get an email when a new federal OSHA severe-injury report for Anthony L. Robinson LLC is published. One employer, no account, unsubscribe in one click.
Site address
1727 LAFAYETTE AVENUE
City
SAINT LOUIS
State
MO
ZIP
63104
Mailing
4246 MCPHERSON AVENUE, SAINT LOUIS, MO 63108
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
3
Ownership type
A

9 citations on file for this inspection.

1926.20 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 21, 2017
Abate by
Jan 10, 2018
Penalty
Initial $2,716 · Current $272 Reduced
29 CFR 1926.20(b)(1): The employer did not initiate and maintain such programs as may be necessary to comply with this part:  At 1727 Lafayette Avenue, St. Louis, MO, the employer did not develop or maintain a safety and health program that addressed safe scaffold erection and use, the wearing of personal protective equipment, and the suitable type and safe use of electrical flexible cords.  This violation was noted on 10/24/17.
Recent events (2)
  • — I (S) $271.6
  • — Z (S) $2716

1926.20 B02

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 21, 2017
Abate by
Jan 10, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s):  At 1727 Lafayette Avenue, St. Louis, MO, on 10/24/17, the employer did not designate a competent person to perform effective inspections of the job site.  The following hazards were noted:  a/  Lack of protective head gear a.k.a. hard hats.  b/  Use of a flexible, extension that was not designed for hard or extra hard usage.  c/  Unsafe use of a flexible, extension cord.   d/  Insufficient planking on a tubular weld standard frame scaffold.  e/  Unsafe access to the tubular weld standard frame scaffold.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.21 B02

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 21, 2017
Abate by
Jan 10, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:  At 1727 Lafayette Avenue, St. Louis, MO, the employer did not perform hazard recognition training for the exposed employees that addressed the electrical and struck-by hazards noted on this job site.  This violation was noted on 10/24/17.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.454 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 21, 2017
Abate by
Jan 10, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.454(a)(1): The employer failed to have each employee who performs work while on a scaffold trained regarding the nature of any electrical hazards, fall hazards and falling object hazards in the work area:  At 1727 Lafayette Avenue, St. Louis, MO, exposed employee(s) were instructed in the nature of fall and falling object hazards while working from a tubular weld standard frame scaffold.  This violation was noted on 10/24/17.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.100 A

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 21, 2017
Abate by
Dec 4, 2017
Penalty
Initial $3,259 · Current $326 Reduced
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:  At 1727 Lafayette Avenue, St. Louis, MO, exposed employee(s) cutting lumber at the base of a tubular weld standard frame scaffold, four tiers high, were not provided with hard hats.  This violation was observed on 10/24/17.
Recent events (2)
  • — I (S) $325.9
  • — Z (S) $3259

1926.405 A02 II I

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 21, 2017
Abate by
Dec 4, 2017
Penalty
Initial $1,630 · Current $163 Reduced
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables were not protected from damage:  At 1727 Lafayette Avenue, St. Louis, MO, the orange, flexible cord supplying 120 volt electrical power to the Ridgid Chop Saw, s/n M56150095A, was placed in the doorway leading into the residence where it was pinched when the door was closed.  This violation was observed on 10/24/17.
Recent events (2)
  • — I (S) $163
  • — Z (S) $1630

1926.405 A02 II J

Serious Gravity 1 1 instance 2 exposed
Issued
Nov 21, 2017
Abate by
Dec 4, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.405(a)(2)(ii)(J): Extension cord sets used with portable electric tools and appliances were not designed for hard or extra-hard usage:  At 1727 Lafayette Avenue, St. Louis, MO, the orange, flexible cord supplying 120 volt electrical power to the Ridgid Chop Saw, s/n M56150095A, was not designed for hard or extra-hard usage.  This violation was observed on 10/24/17.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 21, 2017
Abate by
Dec 4, 2017
Penalty
Initial $3,803 · Current $380 Reduced
29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports:  At 1727 Lafayette Avenue, St. Louis, MO, the tubular weld standard frame scaffold was not fully planked.  Two prefabricated planks were in place where employee(s) were working when four were required to complete the full deck.  The employee(s) were exposed to a 20 foot fall.
Recent events (2)
  • — I (S) $380.3
  • — Z (S) $3803

1926.451 E01

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 21, 2017
Abate by
Dec 4, 2017
Penalty
Initial $3,803 · Current $380 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than two (2) feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used:  At 1727 Lafayette Avenue, St. Louis, MO, the prefabricated ladder belonging to a tubular weld standard frame scaffold was not fully aligned.  The first three sections of ladder were aligned along the north end of each tier.  The fourth and highest section of ladder was positioned along the south end of the tier.  Employee(s) working from this four tier high scaffold were required to cross over from one end of the scaffold to the other when climbing up or down this ladder.  This violation was observed on 10/24/17.
Recent events (2)
  • — I (S) $380.3
  • — Z (S) $3803

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342723343.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.