SAINT LOUIS, MO —
OSHA Inspection: ANTHONY L. ROBINSON LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ANTHONY L. ROBINSON LLC in 1727 LAFAYETTE AVENUE, SAINT LOUIS, MO 63104 (NAICS 238130). OSHA activity number 342723343.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ANTHONY L. ROBINSON LLC
- Site address
- 1727 LAFAYETTE AVENUE
- City
- SAINT LOUIS
- State
- MO
- ZIP
- 63104
- Mailing
- 4246 MCPHERSON AVENUE, SAINT LOUIS, MO 63108
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 3
- Ownership type
- A
Citations
9 citations on file for this inspection.
1926.20 B01
- Issued
- Nov 21, 2017
- Abate by
- Jan 10, 2018
- Penalty
- Initial $2,716 · Current $272 Reduced
General-duty citation text
29 CFR 1926.20(b)(1): The employer did not initiate and maintain such programs as may be necessary to comply with this part: At 1727 Lafayette Avenue, St. Louis, MO, the employer did not develop or maintain a safety and health program that addressed safe scaffold erection and use, the wearing of personal protective equipment, and the suitable type and safe use of electrical flexible cords. This violation was noted on 10/24/17.
Recent events (2)
- — I (S) $271.6
- — Z (S) $2716
1926.20 B02
- Issued
- Nov 21, 2017
- Abate by
- Jan 10, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s): At 1727 Lafayette Avenue, St. Louis, MO, on 10/24/17, the employer did not designate a competent person to perform effective inspections of the job site. The following hazards were noted: a/ Lack of protective head gear a.k.a. hard hats. b/ Use of a flexible, extension that was not designed for hard or extra hard usage. c/ Unsafe use of a flexible, extension cord. d/ Insufficient planking on a tubular weld standard frame scaffold. e/ Unsafe access to the tubular weld standard frame scaffold.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.21 B02
- Issued
- Nov 21, 2017
- Abate by
- Jan 10, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: At 1727 Lafayette Avenue, St. Louis, MO, the employer did not perform hazard recognition training for the exposed employees that addressed the electrical and struck-by hazards noted on this job site. This violation was noted on 10/24/17.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.454 A01
- Issued
- Nov 21, 2017
- Abate by
- Jan 10, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.454(a)(1): The employer failed to have each employee who performs work while on a scaffold trained regarding the nature of any electrical hazards, fall hazards and falling object hazards in the work area: At 1727 Lafayette Avenue, St. Louis, MO, exposed employee(s) were instructed in the nature of fall and falling object hazards while working from a tubular weld standard frame scaffold. This violation was noted on 10/24/17.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.100 A
- Issued
- Nov 21, 2017
- Abate by
- Dec 4, 2017
- Penalty
- Initial $3,259 · Current $326 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: At 1727 Lafayette Avenue, St. Louis, MO, exposed employee(s) cutting lumber at the base of a tubular weld standard frame scaffold, four tiers high, were not provided with hard hats. This violation was observed on 10/24/17.
Recent events (2)
- — I (S) $325.9
- — Z (S) $3259
1926.405 A02 II I
- Issued
- Nov 21, 2017
- Abate by
- Dec 4, 2017
- Penalty
- Initial $1,630 · Current $163 Reduced
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(I): Flexible cords and cables were not protected from damage: At 1727 Lafayette Avenue, St. Louis, MO, the orange, flexible cord supplying 120 volt electrical power to the Ridgid Chop Saw, s/n M56150095A, was placed in the doorway leading into the residence where it was pinched when the door was closed. This violation was observed on 10/24/17.
Recent events (2)
- — I (S) $163
- — Z (S) $1630
1926.405 A02 II J
- Issued
- Nov 21, 2017
- Abate by
- Dec 4, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(a)(2)(ii)(J): Extension cord sets used with portable electric tools and appliances were not designed for hard or extra-hard usage: At 1727 Lafayette Avenue, St. Louis, MO, the orange, flexible cord supplying 120 volt electrical power to the Ridgid Chop Saw, s/n M56150095A, was not designed for hard or extra-hard usage. This violation was observed on 10/24/17.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 B01
- Issued
- Nov 21, 2017
- Abate by
- Dec 4, 2017
- Penalty
- Initial $3,803 · Current $380 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports: At 1727 Lafayette Avenue, St. Louis, MO, the tubular weld standard frame scaffold was not fully planked. Two prefabricated planks were in place where employee(s) were working when four were required to complete the full deck. The employee(s) were exposed to a 20 foot fall.
Recent events (2)
- — I (S) $380.3
- — Z (S) $3803
1926.451 E01
- Issued
- Nov 21, 2017
- Abate by
- Dec 4, 2017
- Penalty
- Initial $3,803 · Current $380 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than two (2) feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used: At 1727 Lafayette Avenue, St. Louis, MO, the prefabricated ladder belonging to a tubular weld standard frame scaffold was not fully aligned. The first three sections of ladder were aligned along the north end of each tier. The fourth and highest section of ladder was positioned along the south end of the tier. Employee(s) working from this four tier high scaffold were required to cross over from one end of the scaffold to the other when climbing up or down this ladder. This violation was observed on 10/24/17.
Recent events (2)
- — I (S) $380.3
- — Z (S) $3803
More inspections in this industry (NAICS 238130)
More inspections in MO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342723343.