Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PYRAMID BIRMINGHAM MANAGEMENT LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PYRAMID BIRMINGHAM MANAGEMENT LLC in 3590 GRANDVIEW PARKWAY, BIRMINGHAM, AL 35243 (NAICS 721110). OSHA activity number 342725702.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pyramid Birmingham Management LLC — free Get an email when a new federal OSHA severe-injury report for Pyramid Birmingham Management LLC is published. One employer, no account, unsubscribe in one click.
Site address
3590 GRANDVIEW PARKWAY
City
BIRMINGHAM
State
AL
ZIP
35243
Mailing
3590 GRANDVIEW PARKWAY, BIRMINGHAM, AL 35243
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
721110
Employees
100
Ownership type
A

2 citations on file for this inspection.

1910.23 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 7, 2017
Abate by
Jan 2, 2018
Penalty
Initial $6,464 · Current $4,525 Reduced
29 CFR 1910.23(b)(2):  Ladder rungs, steps, and cleats were not spaced less than 10 inches (25 cm) and not more than 14 inches (36 cm) apart, as measured between the centerlines of the rungs, cleats, and steps:     (a) On or about 10/17/2017 - Roof top HVAC access room, 15' metal fixed ladder, the distance from the top rung to the top of the metal edge of the hatch was 20 inches exposing employees to falls of approximately 16 feet.
Recent events (2)
  • — I (S) $4524.8
  • — Z (S) $6464

1910.305 B02 I

Other-than-serious 1 instance 1 exposed
Issued
Nov 7, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  (a) On or about 10/24/2017 - Roof top HVAC access room, the faceplate cover was missing on an electrical outlet.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342725702.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.