Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MORONGO CASINO RESORT & SPA

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MORONGO CASINO RESORT & SPA in 49500 SEMINOLE DRIVE, CABAZON, CA 92230 (NAICS 721120). OSHA activity number 342727310.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Morongo Casino Resort & SPA — free Get an email when a new federal OSHA severe-injury report for Morongo Casino Resort & SPA is published. One employer, no account, unsubscribe in one click.
Site address
49500 SEMINOLE DRIVE
City
CABAZON
State
CA
ZIP
92230
Mailing
49500 SEMINOLE DRIVE, CABAZON, CA 92230
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
721120
Employees
1800
Ownership type
A

6 citations on file for this inspection.

1910.37 A03

Serious Gravity 1 1 instance 3 exposed
Issued
Jan 11, 2018
Penalty
Initial $4,005 · Current $3,004 Reduced
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:    Old Maintenance Shop: Stacks of garbage cans and a portable stepladder were stored within the exit route, reducing its width and impeding safe egress. Employees were exposed to fire hazards.
Recent events (2)
  • — I (S) $3003.75
  • — Z (S) $4005

1910.37 B02

Serious Gravity 1 1 instance 3 exposed
Issued
Jan 11, 2018
Abate by
Jan 24, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":  Old Maintenance Shop: The interior door along the exit route did not have an "Exit" sign posted. Employees were exposed to fire hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.110 H14

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 11, 2018
Penalty
Initial $4,005 · Current $3,004 Reduced
29 CFR 1910.110(h)(14): LP gas service station(s) were not provided with at least one approved portable fire extinguisher having at least an 8-B, C rating:    Dock Area: The propane storage tank used for fueling the forklifts did not have a portable fire extinguisher staged near it. Employees were exposed to fire hazards.
Recent events (2)
  • — I (S) $3003.75
  • — Z (S) $4005

1910.242 B

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 11, 2018
Penalty
Initial $4,005 · Current $3,004 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning. Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment.    Engineering Shop: Compressed air used for cleaning purposes was measured to be 60 p.s.i.. Employees were exposed to embolisms and laceration hazards.
Recent events (2)
  • — I (S) $3003.75
  • — Z (S) $4005

1910.303 G01

Serious Gravity 1 1 instance 1 exposed
Issued
Jan 11, 2018
Penalty
Initial $4,005 · Current $3,004 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:    Dock Area: The electrical disconnect switches for the propane tank and the trash compactor had crates stored up against them, not allowing for sufficient clearance. Employees were exposed to electrical, fire, and or entanglement hazards in the event the equipment could not be shut down.
Recent events (2)
  • — I (S) $3003.75
  • — Z (S) $4005

1910.305 G01 IV A

Other-than-serious 1 instance 3 exposed
Issued
Jan 11, 2018
Abate by
Jan 24, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  Old Maintenance Shop: A yellow flexible cord powering the lights was used in lieu of permanent wiring. Employees were exposed to fire and/or electrical shock hazards.