OSHA Inspection: CLEAVER-BROOKS SALES AND SERVICE, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CLEAVER-BROOKS SALES AND SERVICE, INC. in 701 WINTHROP AV, GLENDALE HEIGHTS, IL 60139 (NAICS 238220). OSHA activity number 342730421.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Cleaver-Brooks Sales and Service, INC. — free Get an email when a new federal OSHA severe-injury report for Cleaver-Brooks Sales and Service, INC. is published. One employer, no account, unsubscribe in one click.
Site address
701 WINTHROP AV
City
GLENDALE HEIGHTS
State
IL
ZIP
60139
Mailing
1956 SINGLETON BOULEVARD, DALLAS, TX 75212
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
16
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 II

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Mar 5, 2018
Abate by
Mar 27, 2018
Penalty
Initial $9,239 · Current $0 Reduced
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):  On or about October 13, 2017, employees were exposed to amputation hazards while performing maintenance activities on a Cleaver Brooks boiler model CB-200-250.  The employer's written lockout/tagout program did not include specific procedural steps that clearly stated the necessary steps for machine shut down, the isolation and the securing of hazardous energy, nor did the program provide procedural steps for the placement and removal of lockout devices.  There were no specific requirements or procedures to determine and verify that all hazardous energy was isolated from the mechanical transmission system or other systems of the unit.      Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (3)
  • — F (S) $0
  • — C (S) $9239
  • — Z (S) $9239

1910.147 C06 I

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Mar 5, 2018
Abate by
Mar 27, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  On or about October 13, 2017, employees were exposed to amputation hazards while performing maintenance activities on a Cleaver Brooks boiler model CB-200-250.  The employer did not conduct a periodic inspection of the energy control procedure, at least annually, to ensure that the procedures and the requirements of the standard were being followed.     Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c).
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.147 C04 I

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 5, 2018
Abate by
Mar 27, 2018
Penalty
Initial $12,934 · Current $9,700 Reduced
29 CFR 1910.147(c)(4)(i):     Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.   Note: Exception: The employer need not document the required procedure for a particular machine or equipment, when all of the following elements exist: (1) The machine or equipment has no potential for stored or residual energy or reaccumulation of stored energy after shut down which could endanger employees; (2) the machine or equipment has a single energy source which can be readily identified and isolated; (3) the isolation and locking out of that energy source will completely deenergize and deactivate the machine or equipment; (4) the machine or equipment is isolated from that energy source and locked out during servicing or maintenance; (5) a single lockout device will achieve a locker-out condition; (6) the lockout device is under the exclusive control of the authorized employee performing the servicing or maintenance; (7) the servicing or maintenance does not create hazards for other employees; and (8) the employer, in utilizing this exception, has had no accidents involving the unexpected activation or reenergization of the machine or equipment during servicing or maintenance.
Recent events (3)
  • — F (S) $9700
  • — C (S) $12934
  • — Z (S) $12934

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342730421.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.