Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: OVERSEAS HARDWOODS COMPANY, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of OVERSEAS HARDWOODS COMPANY, INC. in 52333 HWY 225, STOCKTON, AL 36579 (NAICS 321918). OSHA activity number 342733326.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Overseas Hardwoods Company, INC. — free Get an email when a new federal OSHA severe-injury report for Overseas Hardwoods Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
52333 HWY 225
City
STOCKTON
State
AL
ZIP
36579
Mailing
24 TACON STREET, MOBILE, AL 36607
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321918
Employees
43
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 II B

Serious Gravity 5 3 instances 3 exposed
Issued
Feb 8, 2018
Penalty
Initial $3,958 · Current $3,807 Reduced
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedure did not clearly and specifically specific procedural steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy:  a)  Finger Jointer #2;  On or about October 25, 2017 and at times prior thereto, employees engaged in servicing and maintenance activities on Finger Jointer #2 were exposed to the pneumatic energy present on the machine in that the energy control procedure did not identify specific procedural steps for controlling this hazardous energy.  b)  Woods 412 Matcher;  On or about October 25, 2017 and at times prior thereto, employees engaged in servicing and maintenance activities on Woods 412 Matcher were exposed to the pneumatic energy present on the machine in that the energy control procedure did not identify specific procedural steps for controlling this hazardous energy.  c)  Chopsaw #2;  On or about October 25, 2017 and at times prior thereto, employees engaged in servicing and maintenance activities on Chopsaw #2 potentially exposed to the pneumatic energy present on the machine in that the energy control procedure did not identify specific procedural steps for controlling this hazardous energy.
Recent events (2)
  • — I (S) $3807
  • — Z (S) $3958

1910.147 C06 II

Serious Gravity 5 1 instance 3 exposed
Issued
Feb 8, 2018
Abate by
Feb 28, 2018
Penalty
Initial $4,656 · Current $3,807 Reduced
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed:  a)  Equipment in the facility;  On or about October 25, 2017 and at times prior thereto, the employer failed to certify that periodic inspections with authorized employees who perform servicing and maintenance on equipment including but not limited to, Air Dryer #1, Chopsaw #2, and Finger Jointer #2, had been performed to ensure these employees were performing the written energy control procedures correctly.
Recent events (2)
  • — I (S) $3807
  • — Z (S) $4656

1910.147 C06 I

Serious Gravity 5 3 instances 3 exposed
Issued
Feb 8, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  a)  Finger Jointer #2;  On or about October 25, 2017 and at times prior thereto, the employer exposed employees to the hazardous energy present on Finger Jointer #2 in that the employer failed to perform a periodic review of the energy control procedures at least annually to ensure the procedures were correct.  b)  Chopsaw #2;  On or about October 25, 2017 and at times prior thereto, the employer exposed employees to the hazardous energy present on Chopsaw #2 in that the employer failed to perform a periodic review of the energy control procedures at least annually to ensure the procedures were correct.  c)  Air Dryer #1;  On or about October 25, 2017 and at times prior thereto, the employer exposed employees to the hazardous energy present on Air Dryer #1 in that the employer failed to perform a periodic review of the energy control procedures at least annually to ensure the procedures were correct.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Overseas Hardwoods Company, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342733326.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.