MUNCY, PA —
OSHA Inspection: PENN-AMERICAN INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PENN-AMERICAN INC in 6840 SUSQUEHANNA TRAIL P.O. BOX 240, MUNCY, PA 17756 (NAICS 332999). OSHA activity number 342734639.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PENN-AMERICAN INC
- Site address
- 6840 SUSQUEHANNA TRAIL P.O. BOX 240
- City
- MUNCY
- State
- PA
- ZIP
- 17756
- Mailing
- 6840 SUSQUEHANNA TRAIL, MUNCY, PA 17756
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332999
- Employees
- 25
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.212 A03 II
- Issued
- Jan 31, 2018
- Abate by
- Feb 20, 2018
- Penalty
- Initial $3,696 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): (a) Fabrication Shop: The employer did not provide point of operation guarding on the Cyril Bath 150 Ton Mechanical Press Brake Model 15010, exposing employees to a potential amputation and/or crushing injury, on or about October 27, 2017. Abatement Certification Required
Recent events (2)
- — I (S) $2000
- — Z (S) $3696
1910.147 C06 I
- Issued
- Jan 31, 2018
- Abate by
- Feb 27, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) At the Facility: An inspection of the energy control procedures (Lockout/Tagout) was not conducted at least annually by the employer, as observed on or about October 27, 2017. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS VIOLATION.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Penn-American INC
View Penn-American INC's full OSHA safety record →
More inspections in this industry (NAICS 332999)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342734639.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.