RANCHO MIRAGE, CA —
OSHA Inspection: AGUA CALIENTE CASINO RESORT SPA
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of AGUA CALIENTE CASINO RESORT SPA in 32250 BOB HOPE DRIVE, RANCHO MIRAGE, CA 92270 (NAICS 721120). OSHA activity number 342737285.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AGUA CALIENTE CASINO RESORT SPA
- Site address
- 32250 BOB HOPE DRIVE
- City
- RANCHO MIRAGE
- State
- CA
- ZIP
- 92270
- Mailing
- 32250 BOB HOPE DRIVE, RANCHO MIRAGE, CA 92270
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 721120
- Employees
- 1344
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.215 B09
- Issued
- Jan 9, 2018
- Penalty
- Initial $4,005 · Current $2,804 Reduced
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: Engineering Shop: The tongue guard on the right side of the Dayton bench grinder was 1 inch from the abrasive wheel. Employees were exposed to struck-by hazards.
Recent events (2)
- — I (S) $2803.5
- — Z (S) $4005
1910.242 B
- Issued
- Jan 9, 2018
- Penalty
- Initial $4,005 · Current $2,804 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning. Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment. Engineering Shop: Compressed air used for cleaning purposes was measured to be 60 p.s.i.. Employees were exposed to embolisms and laceration hazards.
Recent events (2)
- — I (S) $2803.5
- — Z (S) $4005
1910.303 B02
- Issued
- Jan 9, 2018
- Penalty
- Initial $4,005 · Current $2,804 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: Engineering Shop: The Belkin relocatable power tap was used to provide power to equipment, such as but not limited to a DeWalt Orbital Sander, and did not comply with listed and labeling requirements: a) An extension cord was daisy-chained to the relocatable power tap. b) The relocatable power tap was secured to a workbench. c) The relocatable power tap was used in an industrial setting. Employees were exposed to electrical and fire hazards.
Recent events (2)
- — I (S) $2803.5
- — Z (S) $4005
1910.305 G01 IV C
- Issued
- Jan 9, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(C): Flexible cords and cables were run through dorways, windows or floors. Laundry Room: The power cord for the Tornado Windshear SD3500 was run through an open doorway and plugged into a power outlet. Employees were exposed to electrical hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Agua Caliente Casino Resort SPA
View Agua Caliente Casino Resort SPA's full OSHA safety record →
More inspections in this industry (NAICS 721120)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342737285.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.