BAYTOWN, TX —
OSHA Inspection: CERTIFIED PIPE SERVICE HOUSTON, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CERTIFIED PIPE SERVICE HOUSTON, INC. in 6225 FM 1942 RD., BAYTOWN, TX 77521 (NAICS 332812). OSHA activity number 342740123.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CERTIFIED PIPE SERVICE HOUSTON, INC.
- Site address
- 6225 FM 1942 RD.
- City
- BAYTOWN
- State
- TX
- ZIP
- 77521
- Mailing
- 301 S. SHELDON RD., CHANNELVIEW, TX 77530
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332812
- Employees
- 53
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.178 P01
- Issued
- Dec 6, 2017
- Penalty
- Initial $8,149 · Current $4,075 Reduced
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s) On or about October 30, 2017 throughout the facility where employees were exposed to struck-by hazards while operating John Deere 644K forklifts SN: 1DW644KCDE655255, 1DW644KZTDE654253, and 1DW644KZCDE656325 that were observed to have non operative headlights and turn signals.
Recent events (2)
- — I (O) $4074.5
- — Z (S) $8149
1910.242 B
- Issued
- Dec 6, 2017
- Penalty
- Initial $6,519 · Current $3,260 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: On or about October 30, 2017 at the CNC facility where employees were exposed to struck-by and injection hazards while blowing off equipment without reducing the air pressure below 30 p.s.i.
Recent events (2)
- — I (O) $3259.5
- — Z (S) $6519
1910.303 F02
- Issued
- Dec 6, 2017
- Penalty
- Initial $8,149 · Current $4,075 Reduced
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: On or about October 30, 2017 at the plasma cutting building and CNC shop where three breaker boxes were not labeled to identify each breaker and or switch.
Recent events (2)
- — I (S) $4074.5
- — Z (S) $8149
1910.305 B01 II
- Issued
- Dec 6, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: On or about October 30, 2017 at the CNC shop where employees were exposed to electrical hazards when using electrical boxes that had unused openings.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at Certified Pipe Service Houston, INC.
View Certified Pipe Service Houston, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332812)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342740123.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.