Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: T.L. WALLACE CONSTRUCTION, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of T.L. WALLACE CONSTRUCTION, INC. in 12618 WEST I-20 EAST, ODESSA, TX 79765 (NAICS 237310). OSHA activity number 342742871.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch T.L. Wallace Construction, INC. — free Get an email when a new federal OSHA severe-injury report for T.L. Wallace Construction, INC. is published. One employer, no account, unsubscribe in one click.
Site address
12618 WEST I-20 EAST
City
ODESSA
State
TX
ZIP
79765
Mailing
4025 MS-35, COLUMBIA, MS 39429
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237310
Employees
298
Ownership type
A

7 citations on file for this inspection.

1926.102 A01

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Jan 2, 2018
Abate by
Jan 22, 2018
Penalty
Initial $7,243 · Current $0 Reduced
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical agents:  At 12618 west I-20 on or about June 26, 2017 employees were exposed to eye injuries while working with electric impact wrenches without eye protection.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7243

1926.501 B04 I

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Jan 2, 2018
Abate by
Jan 22, 2018
Penalty
Initial $12,675 · Current $0 Reduced
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected arou  At 12618 west I-20 on or about June 26, 2017, employees were exposed to fall hazards greater than 6 feet in height while working on the top of a steel frame building under demolition without fall protection.
Recent events (2)
  • — I (S) $0
  • — Z (S) $12675

1926.503 A01

Deleted Serious Gravity 1 1 instance 2 exposed
Issued
Jan 2, 2018
Abate by
Jan 22, 2018
Penalty
Initial $5,432 · Current $0 Reduced
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:   At 12618 west I-20 on or about June 26, 2017 employees were exposed to fall hazards greater than 6 feet in height while working on the roof of a building being demolished without fall protection training.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5432

1926.850 A

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Jan 2, 2018
Abate by
Jan 22, 2018
Penalty
Initial $7,243 · Current $0 Reduced
29 CFR 1926.850(a): Evidence in writing was not available that an engineering survey performed by a competent person had been performed prior to permitting employee(s) to start demolition operations:  At 12618 west I-20 on or about June 26, 2017 employees were exposed to illness and injury while working on a demolition project that was not properly surveyed by an engineer.
Recent events (2)
  • — I (S) $0
  • — Z (S) $7243

1926.850 C

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Jan 2, 2018
Abate by
Jan 22, 2018
Penalty
Initial $10,864 · Current $0 Reduced
29 CFR 1926.850(c): All electric, gas, water, steam, sewer, and other service lines were not shut off, capped, or otherwise controlled, outside the building line before demolition work was started. In each case, any utility company which was involved was not notified in advance  At 12618 west I-20 on or about June 26, 2017, employees were exposed to electrical shock hazards while moving electrical conductive materials in close proximity to energized electrical power lines.
Recent events (2)
  • — I (S) $0
  • — Z (S) $10864

1926.960 C01 I

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Jan 2, 2018
Abate by
Jan 22, 2018
Penalty
Initial $7,243 · Current $0 Reduced
29 CFR 1926.960(c)(1)(i): The employer did not establish minimum approach distances (MAD) no less than the distances computed by Table V-2 for ac systems:  At 12618 west I-20 on or about June 26, 2017 employees were exposed to electrical shock hazards while working in close proximity to live electrical power lines
Recent events (2)
  • — I (S) $0
  • — Z (S) $7243

1926.960 C01 III

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Jan 2, 2018
Abate by
Jan 22, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.960(c)(1)(iii): 29 CFR 1926.960(c)(1)(iii): The employer did not ensure that employees would not approach or take any conductive object closer to exposed energized parts than the employer's established minimum approach distance, unless the measures outlined in 1926.960(c)(1)(iii)(A) - (C) were met:  At 12618 west I-20 on or about June 26, 2017 employees were exposed to electrical shock hazards while moving conductive materials in close proximity to energized electrical power lines.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View T.L. Wallace Construction, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342742871.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.