Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HO-HO-KUS INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of HO-HO-KUS INC in 189-201 LYON STREET, PATERSON, NJ 07524 (NAICS 336411). OSHA activity number 342743994.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ho-Ho-Kus INC — free Get an email when a new federal OSHA severe-injury report for Ho-Ho-Kus INC is published. One employer, no account, unsubscribe in one click.
Establishment
HO-HO-KUS INC
Site address
189-201 LYON STREET
City
PATERSON
State
NJ
ZIP
07524
Mailing
189-201 LYON STREET, PATERSON, NJ 07524
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336411
Employees
50
Ownership type
A

9 citations on file for this inspection.

1910.36 A02

Serious Gravity 5 1 instance 50 exposed
Issued
Apr 13, 2018
Abate by
May 9, 2018
Penalty
Initial $6,467 · Current $6,467
29 CFR 1910.36(a)(2): An exit must be separated by fire resistant materials. Construction materials used to separate an exit from other parts of the workplace must have a one-hour fire resistance-rating if the exit connects three or fewer stories and a two-hour fire resistance-rating if the exit connects four or more stories.   a) Main exit: A wooden door that separated an exit from the workplace did not have a fire resistance-rating, on or about 10/13/2017.
Recent events (3)
  • — F (S) $6467
  • — C (S) $6467
  • — Z (S) $6467

1910.36 D01

Serious Gravity 5 7 instances 50 exposed
Issued
Apr 13, 2018
Abate by
Apr 25, 2018
Penalty
Initial $6,467 · Current $6,467
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:   a) Stamping room: The Exit Door had two turn knob locks that were kept in the locked position during the 1st and 2nd shifts, on or about 10/27/2017.    b) Paint Room Exit door: The Exit Door had two turn knob locks that were kept in the locked position during the 1st and 2nd shifts, on or about 10/27/2017.
Recent events (3)
  • — F (S) $6467
  • — C (S) $6467
  • — Z (S) $6467

1910.37 A03

Serious Gravity 5 1 instance 50 exposed
Issued
Apr 13, 2018
Abate by
May 31, 2018
Penalty
Initial $6,467 · Current $6,467
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed:   a) Stamping room. The exit route from the Stamping Room and Paint Room were obstructed by three guard dogs, thus exposing employees to dog bites and fire hazard, on or about 10/27/2017.
Recent events (3)
  • — F (S) $6467
  • — C (S) $6467
  • — Z (S) $6467

1910.37 B02

Serious Gravity 5 1 instance 50 exposed
Issued
Apr 13, 2018
Penalty
Initial $6,467 · Current $6,467
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":   a) Stamping Room. The two doors in the stamping room were not marked Exit or similar designation by a sign indicating its actual use, on or about 10/27/2017.
Recent events (3)
  • — F (S) $6467
  • — C (S) $6467
  • — Z (S) $6467

1910.37 B04

Serious Gravity 5 1 instance 50 exposed
Issued
Apr 13, 2018
Penalty
Initial $6,467 · Current $6,467
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent:   a) Facility: Directional signs indicating the direction of travel to nearest exit were not installed to guide employees to safety in the event of emergency, on or about 10/27/2017.
Recent events (3)
  • — F (S) $6467
  • — C (S) $6467
  • — Z (S) $6467

1910.138 A

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 13, 2018
Penalty
Initial $3,880 · Current $3,880
29 CFR 1910.138(a): The employer did not select and require employee(s) to use appropriate hand protection when employees' hands were exposed to hazards such as those from severe cuts or lacerations:   a) Assembly Area: Employees using razor blades for de-burring were exposed to a laceration or severe cuts without the use of hand protection, on or about 10/27/2017.
Recent events (3)
  • — F (S) $3880
  • — C (S) $3880
  • — Z (S) $3880

1910.212 B

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 13, 2018
Penalty
Initial $5,174 · Current $5,174
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:    a) Tool Room: A Delta Tool grinder was not anchored to prevent moving, on or about 10/27/2017.
Recent events (3)
  • — F (S) $5174
  • — C (S) $5174
  • — Z (S) $5174

1910.36 C02

Serious Gravity 5 5 instances 50 exposed
Issued
Apr 13, 2018
Penalty
Initial $77,599 · Current $12,934 Reduced
29 CFR 1910.36(c)(2): The street, walkway, refuge area, public way, or open space to which an exit discharge leads must be large enough to accommodate the building occupants likely to use the exit route.     a) Main exit door: The exit gate beyond the designated discharge was locked with a chain and master lock, thus exposing employees to fire and smoke inhalation hazard.  The employees would be unable to leave the open space that is not large enough to accommodate them, on or about 10/13/2017.       b) Main exit door: The exit gate beyond the designated discharge was locked with a chain and master lock, thus exposing employees to fire and smoke inhalation hazard.  The employees would be unable to leave the open space that is not large enough to accommodate them, on or about 10/27/2017.    c) Stamping room: The exit gate beyond the designated discharge was locked with a chain and master lock, thus exposing employees to fire and smoke inhalation hazard.  The employees would be unable to leave the open space that is not large enough to accommodate them, on or about 2/05/2017.      d) Main exit door: The exit gate beyond the designated discharge was locked with a chain and master lock, thus exposing employees to fire and smoke inhalation hazard.  The employees would be unable to leave the open space that is not large enough to accommodate them, on or about 2/05/2018.    e) Main exit door: The exit gate beyond the designated discharge was locked with a chain and master lock, thus exposing employees to fire and smoke inhalation hazard.  The employees would be unable to leave the open space
Recent events (3)
  • — F (S) $12934
  • — C (W) $77599
  • — Z (W) $77599

1910.1200 G08

Other-than-serious 1 instance 1 exposed
Issued
Apr 13, 2018
Abate by
May 9, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(g)(8):   The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work  shift to employees when they were in their work area(s)  a) Slotter Room: The employer did not have safety data sheet for 73XNW Reconditioner, on or about 02/08/2018.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

View Ho-Ho-Kus INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342743994.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.