OSHA Inspection: POWER AND COMPOSITE TECHNOLOGIES LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of POWER AND COMPOSITE TECHNOLOGIES LLC in 200 WALLINS CORNERS ROAD, AMSTERDAM, NY 12010 (NAICS 326199). OSHA activity number 342745304.

Watch Power AND Composite Technologies LLC — free Get an email when a new federal OSHA severe-injury report for Power AND Composite Technologies LLC is published. One employer, no account, unsubscribe in one click.
Site address
200 WALLINS CORNERS ROAD
City
AMSTERDAM
State
NY
ZIP
12010
Mailing
200 WALLINS CORNERS ROAD, AMSTERDAM, NY 12010
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
326199
Employees
110
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 5 20 instances 120 exposed
Issued
Abate by
Penalty
Initial $9147.00 · Current $5488.00 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which is free from recognized hazards that were likely to cause death or serious physical harm to employees in that employees were exposed to fire, deflagration, and explosion hazards from ST-1 combustible fiber-reinforced plastic dust(s).      On or prior to 11/03/17, exterior baghouse-type dust collectors and interior enclosureless-type dust collector(s) used in processes including but not limited to:  cutting, machining, and sanding of fiber-reinforced plastic materials, were not designed, installed and maintained to protect employees from fire and explosion hazards in that:      (a) Wallins Corners and Genesee Lane Facilities -- Exterior baghouse and interior enclosureless dust collector(s) utilized in processes producing combustible dust(s) were not equipped with explosion and deflagration protection.    (b) Wallins Corners and Genesee Lane Facilities -- Inlet and return air ductwork for baghouse dust collector(s) was not equipped with explosion and deflagration protection to prevent an explosion or flame-front from propagating through the ductwork and back into the facility.    (c) Wallins Corners and Genesee Lane Facilities -- Inlet ductwork for baghouse and enclosureless dust collector(s) was   not designed to control static ignition hazards.
Recent events (4)
  • — P (S) $5488
  • — F (S) $5488
  • — C (S) $9147