OSHA Inspection: RODRIGO JAVIER MEJIA HERNANDEZ

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of RODRIGO JAVIER MEJIA HERNANDEZ in 1084 HOWELL MILL ROAD, ATLANTA, GA 30303 (NAICS 238130). OSHA activity number 342746369.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rodrigo Javier Mejia Hernandez — free Get an email when a new federal OSHA severe-injury report for Rodrigo Javier Mejia Hernandez is published. One employer, no account, unsubscribe in one click.
Site address
1084 HOWELL MILL ROAD
City
ATLANTA
State
GA
ZIP
30303
Mailing
1281 BROCKETT ROAD, APT. 15N, CLARKSTON, GA 30021
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
10
Ownership type
A

2 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 28, 2018
Penalty
Initial $2,217 · Current $1,330 Reduced
29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:    (a) Broadstone Westside Apartments, Fourth level of framing: On or about 11/01/2017, and at times prior, the employer exposed employees to struck-by hazards while operating pneumatic framing nail guns at 120 PSI, in that protective eyewear was not provided while erecting guardrails on the edges of the walking/working surface.
Recent events (2)
  • — I (S) $1330.2
  • — Z (S) $2217

1926.501 B13

Serious Gravity 10 2 instances 3 exposed
Issued
Mar 28, 2018
Penalty
Initial $3,880 · Current $2,328 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:     (a) Broadstone Westside Apartments, Fourth level of framing (6th floor): On or about 11/01/2017, and at times prior, the employer exposed employees to fall hazards of approximately 31-feet, 9-inches to the lower ground level, in that employees erecting guardrails at the edge of the walking/working surface were not provided with a fall protection system.     (b) Broadstone Westside Apartments, Fourth level of framing(6th floor): On or about 11/01/2017, and at times prior, the employer exposed employees to fall hazards of approximately 31-feet, 9-inches and greater to the lower ground level, in that guardrails were not installed along all open ends of the walking/working surface.
Recent events (2)
  • — I (S) $2328
  • — Z (S) $3880