Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ATTIC BREEZE, LLC

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of ATTIC BREEZE, LLC in 1370 FM 116, GATESVILLE, TX 76528 (NAICS 333411). OSHA activity number 342749157.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Attic Breeze, LLC — free Get an email when a new federal OSHA severe-injury report for Attic Breeze, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
ATTIC BREEZE, LLC
Site address
1370 FM 116
City
GATESVILLE
State
TX
ZIP
76528
Mailing
1370 FM 116, GATESVILLE, TX 76528
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333411
Employees
26
Ownership type
A

3 citations on file for this inspection.

1910.134 E01

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 15, 2017
Abate by
Jan 22, 2018
Penalty
Initial $5,070 · Current $2,788 Reduced
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employees ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:       In the manufacturing facility, the employer did not provide medical evaluation for employees required to use respirators.
Recent events (2)
  • — I (S) $2788
  • — Z (S) $5070

1910.134 F02

Serious Gravity 5 1 instance 3 exposed
Issued
Dec 15, 2017
Abate by
Jan 17, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(2): The employer did not ensure that an employee using a tight-fitting facepiece respirators is fit tested prior to initial use of the respirator, whenever a different respirator facepiece (size, style, model or make) is used, and at least annually thereafter:      In the manufacturing facility, employees required to use respirators were not fit tested prior to respirator use and annually, exposing them to physiological hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H03 III

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 15, 2017
Abate by
Jan 22, 2018
Penalty
Initial $8,873 · Current $4,880 Reduced
29 CFR 1910. 1200(h)(3)(iii): Employee training did not include the measures employees can take to protect themselves from these hazards, including specific procedures the employer has  implemented to protect employees from exposure to hazardous chemicals, such as appropriate work practices, emergency procedures and personal protective equipment to be used:         In the powder coating area, powder coating employees were not trained on how to clean and where to dispose flammable residue, exposing employees to fire hazards.
Recent events (2)
  • — I (S) $4880
  • — Z (S) $8873

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342749157.