HUMBLE, TX —
OSHA Inspection: AZTEC INDUSTRIES, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of AZTEC INDUSTRIES, INC. in 14621 MARINE RD., HUMBLE, TX 77396 (NAICS 332312). OSHA activity number 342749306.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- AZTEC INDUSTRIES, INC.
- Site address
- 14621 MARINE RD.
- City
- HUMBLE
- State
- TX
- ZIP
- 77396
- Mailing
- 14621 MARINE RD., HUMBLE, TX 77396
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 15
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.253 B04 III
- Issued
- Feb 6, 2018
- Abate by
- Apr 6, 2018
- Penalty
- Initial $3,696 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least 1 half hour. On or about November 2, 2017 at the facility where employees were exposed to a fire hazard when acetylene cylinders were stored with oxygen cylinders without being separated by a minimum distance of 20 feet or by a noncombustible barrier at least 5 feet high with a 1 hour fire rating.
Recent events (2)
- — I (S) $2000
- — Z (S) $3696
1910.303 F02
- Issued
- Feb 6, 2018
- Abate by
- Mar 2, 2018
- Penalty
- Initial $3,696 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: On or about November 2, 2017 at the fabrication shop where two breaker boxes were not labeled to identify each breaker and or switch.
Recent events (2)
- — I (S) $2000
- — Z (S) $3696
1910.305 B01 II
- Issued
- Feb 6, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a. On or about November 2, 2017 at the fabrication shop, where employees were exposed to electrical hazards when accessing an Eaton breaker box which had missing breakers or blanks. b. On or about November 2, 2017 at the fabrication shop, where employees were exposed to electrical hazards when working near a disconnect box which was missing a knock out. c. On or about November 2, 2017 at the fabrication shop, where employees were exposed to electrical hazards when accessing a GE breaker box which had missing breakers or blanks and a missing knock out.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 G02 I
- Issued
- Feb 6, 2018
- Penalty
- Initial $3,696 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by Subpart S of Part 1910, live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the means identified in paragraphs (A), (B), (C), and (D) of 29 CFR 1910.303(g)(2)(i): On or about November 2, 2017 at the fabrication shop where employees were exposed to electrical hazards when using electrical wall outlets, a light switch, and a breaker box where the cover was missing or broken.
Recent events (2)
- — I (S) $2000
- — Z (S) $3696
1910.305 G02 III
- Issued
- Feb 6, 2018
- Abate by
- Mar 2, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws: On or about November 2, 2017 at the fabrication shop where employees were exposed to electrical hazards when using welding machines whose power cables were connected to the breaker box without having strain relief.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 E01
- Issued
- Feb 6, 2018
- Abate by
- Apr 6, 2018
- Penalty
- Initial $3,696 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: On or about November 2, 2017, where employees were using compressed gases such as, but not limited to, acetylene, propylene, argon, and diesel fuel without a written hazard communication program in place.
Recent events (2)
- — I (S) $2000
- — Z (S) $3696
1910.1200 H01
- Issued
- Feb 6, 2018
- Abate by
- Apr 6, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: On or about November 2, 2017, where employees were using compressed gases such as, but not limited to, acetylene, propylene, argon, and diesel fuel and had not been trained on the hazards of the chemicals they use.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 G01
- Issued
- Feb 6, 2018
- Abate by
- Apr 6, 2018
- Penalty
- Initial $3,696 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use. On or about November 2, 2017, where employees worked with compressed gases such as, but not limited to, acetylene, propylene, argon, and diesel fuel without the employer having safety data sheets available.
Recent events (2)
- — I (S) $2000
- — Z (S) $3696
More inspections at Aztec Industries, INC.
View Aztec Industries, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332312)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342749306.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.