Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: D & C DRILLING, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of D & C DRILLING, LLC in 100 CROY CREEK ROAD, HAILEY, ID 83333 (NAICS 237110). OSHA activity number 342753936.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch D & C Drilling, LLC — free Get an email when a new federal OSHA severe-injury report for D & C Drilling, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
D & C DRILLING, LLC
Site address
100 CROY CREEK ROAD
City
HAILEY
State
ID
ZIP
83333
Mailing
3315 SOUTH 2000 EAST, WENDELL, ID 83355
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
2
Ownership type
A

7 citations on file for this inspection.

1926.251 A06

Serious Gravity 10 1 instance 3 exposed
Issued
Jan 4, 2018
Abate by
Jan 17, 2018
Penalty
Initial $3,803 · Current $1,902 Reduced
29 CFR 1926.251(a)(6): Each day before being used, and during use, where service conditions warrant, the sling and all fastenings and attachments were not inspected for damage or defects by a competent person, and damaged or defective slings were not immediately removed from service:    a) Jobsite: On or about October 31, 2017 and at times prior thereto employees performed well drilling activities using an Ingersoll Rand T3 well drill.  A competent person had not completed an inspection prior to using the sling (wire cable) and associated hardware.  The correct number of U-bolt clips were not in place on a 5/16 inch wire cable used to hoist and hold drill stems.  U-bolt clips were installed backwards and not properly spaced on a 1/2 inch wire cable also used to hoist and support drill stems and/or casings.         b) Jobsite: On or about October 31, 2017 and at times prior thereto employees performed well drilling activities using an Ingersoll Rand T3 well drill.  A competent person had not completed an inspection prior to using the sling (wire cable) and associated hardware.  The 5/16 wire cable that hoisted and supported the drill stem was looped.  The defective wire cable had not been identified and immediately corrected or removed from service.      c) Jobsite: On or about October 31, 2017 and at times prior thereto employees performed well drilling activities using an Ingersoll Rand T3 well drill.  A competent person had not completed an inspection prior to using the sling (chains) and associated hardware.  The three chains used around the casing were not positively secured to the casing clamp to prevent the chains from becoming slack or dislodged, before and through-out the well drilling activities.           Note) Certification and documentation of corrective action are required.
Recent events (2)
  • — I (S) $1901.5
  • — Z (S) $3803

1926.251 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 4, 2018
Abate by
Jan 17, 2018
Penalty
Initial $2,173 · Current $1,087 Reduced
29 CFR 1926.251(b)(1): Welded alloy steel chain sling(s) did not have permanently affixed durable identification stating size, grade, rated capacity, and sling manufacturer:    a) Jobsite: On or about October 31, 2017 and at times prior thereto employees performed well drilling activities using a Ingersoll Rand T3 well drill.  Steel chains attached to the casing clamp assembly were used to hoist and hold the casing pipe.  The chains did not have any identification markings attached.       Note) Certification of corrective action is required for this item.
Recent events (2)
  • — I (S) $1086.5
  • — Z (S) $2173

1926.251 B06 II

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 4, 2018
Abate by
Jan 17, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.251(b)(6)(ii): The employer did not make or maintain a record of the most recent month in which each alloy steel chain sling was thoroughly inspected:  a) Jobsite: On or about October 31, 2017 and at times prior thereto employees performed well drilling activities using a Ingersoll Rand T3 well drill.  Inspection documentation was not maintained for the casing clamp chains used for hoisting and holding the casing.   Note) Certification of corrective action is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.251 C16

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 4, 2018
Abate by
Jan 17, 2018
Penalty
Initial $0 · Current $0
29 CFR 1926.251(c)(16): Wire rope slings did not have permanently affixed, legible identification markings stating size, rated capacity for the type(s) of hitch(es) used:   a) Jobsite: On or about October 31, 2017 and at times prior thereto employees performed well drilling activities using a Ingersoll Rand T3 well drill.  Rated capacity identification markings were not in place on a 5/16 inch wire cable and a 1/2 inch wire cable, both used to hoist and support drill stems and/or the casing.     Note) Certification of corrective action is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.251 C05

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Jan 4, 2018
Abate by
Jan 17, 2018
Penalty
Initial $2,173 · Current $0 Reduced
29 CFR 1926.251(c)(5): When U-bolt wire rope clips are used to form eyes, Table H-20 was not used to determine the number and spacing of clips:    a) Jobsite: On or about October 31, 2017 and at times prior thereto employees used a 5/16 wire cable to hoist and hold drill stems for a Ingersoll Rand T3 well drill. Only two U-bolt clips were in place on each eye of the wire cable used to hoist and support drill stems.       Note) 29 CFR 1926.251, Table H-20 requires three properly spaced U-bolt clips when using 5/16 wire cable.      Note) Certification of corrective action is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2173

1926.251 C05 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 4, 2018
Abate by
Jan 17, 2018
Penalty
Initial $0 · Current $1,087
29 CFR 1926.251(c)(5)(i): When used for eye splices, the U-bolt was not applied so that the "U" section is in contact with the dead end of the rope:    a) Jobsite: On or about October 31, 2017 and at times prior thereto hardware on the wire cable used with the casing clamp and drill stem hook, was not installed properly.  One out of three U-bolt clips on each eye of the wire cable were installed backwards, in that the "U" section was contacting the live end of the cable.  Employees used a wire cable to hoist and hold the casing clamp, casing and/or drill stem.        Note) Certification of corrective action is required for this item.
Recent events (2)
  • — I (S) $1086.5
  • — Z (S) $0

1904.39 A02

Other-than-serious 1 instance 2 exposed
Issued
Jan 4, 2018
Abate by
Jan 10, 2018
Penalty
Initial $2,716 · Current $1,358 Reduced
29 CFR 1904.39(a)(2): The employer did not report to OSHA within twenty-four (24) hours after the in-patient hospitalization of one or more employees or an employee's amputation or an employee's loss of an eye resulting from a work-related incident:    a) On or about October 31, 2017 an employee was hospitalized as a result of a work place injury.  The employer did not make the necessary notification of the incident to OSHA.     Note) Certification of corrective action is required for this item.
Recent events (2)
  • — I (O) $1358
  • — Z (O) $2716

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342753936.