MILES CITY, MT —
OSHA Inspection: MAC'S FRONTIERLAND, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MAC'S FRONTIERLAND, INC. in 3016 VALLEY DRIVE, MILES CITY, MT 59301 (NAICS 441110). OSHA activity number 342754322.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MAC'S FRONTIERLAND, INC.
- Site address
- 3016 VALLEY DRIVE
- City
- MILES CITY
- State
- MT
- ZIP
- 59301
- Mailing
- 3016 VALLEY DRIVE, MILES CITY, MT 59301
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 441110
- Employees
- 14
- Ownership type
- A
Citations
8 citations on file for this inspection.
5(a)(1)
- Issued
- Mar 5, 2018
- Abate by
- Mar 29, 2018
- Penalty
- Initial $2,513 · Current $1,257 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck-by hazards: a) Westside Shop: On November 6, 2017 and at times prior, employees were exposed to struck-by hazards from a 3/4" polyvinyl chloride (PVC) used to transfer compressed air. b) Automotive Lift #2: On November 6, 2017 and at times prior, employees were exposed to struck-by hazards while elevating vehicles with faulty telescoping arm stops. c) Automotive Lift #8: On November 6, 2017 and at times prior, employees were exposed to struck-by hazards while elevating vehicles with faulty telescoping arm stops.
Recent events (2)
- — I (S) $1256.5
- — Z (S) $2513
1910.28 B01 I
- Issued
- Mar 5, 2018
- Abate by
- Mar 29, 2018
- Penalty
- Initial $1,885 · Current $943 Reduced
General-duty citation text
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following: Guardrail systems, safety net systems, or personal fall arrest systems: a) West Shop: On November 6, 2017 and at times prior, employees were exposed to fall hazards of approximately 7 feet 9 inches while servicing a heater on an unprotected mezzanine.
Recent events (2)
- — I (S) $942.5
- — Z (S) $1885
1910.28 B11 II
- Issued
- Mar 5, 2018
- Abate by
- Mar 29, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.28(b)(11)(ii): Each flight of stairs having at least 3 treads and at least 4 risers was not equipped with stair rail systems and handrails as required in Table D-2 of this standard: a) West Shop: On November 6, 2017 and at times prior employees were exposed to fall hazards of approximately 14 risers and runs while accessing and egressing an unprotected stairway.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Mar 5, 2018
- Abate by
- Mar 29, 2018
- Penalty
- Initial $2,513 · Current $1,257 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Tool Room: On November 6, 2017 and at times prior, employees were exposed to struck by hazards while using an unguarded 17 1/2 Ton OTC Shop Press.
Recent events (2)
- — I (S) $1257
- — Z (S) $2513
1910.37 B02
- Issued
- Mar 5, 2018
- Abate by
- Mar 29, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": a) Detail Area: On November 6, 2017 and at times prior, the employer failed to mark the doorway leading outside as an "Exit". b) West Shop: On November 6, 2017 and at times prior, the employer failed to mark the doorway leading outside as an "Exit". c) East Shop: On November 6, 2017 and at times prior, the employer failed to mark the doorway leading outside as an "Exit".
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.37 B05
- Issued
- Mar 5, 2018
- Abate by
- Mar 29, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet): a) West Shop: On November 6, 2017 and at times prior, the employer failed to mark the doorway leading to the office area as "Not an Exit". b) East Shop: On November 6, 2017 and at times prior, the employer failed to mark the doorway leading to the wash room area as "Not an Exit". c) Tool Room: On November 6, 2017 and at times prior, the employer failed to mark the doorway leading to tool room area as "Not an Exit".
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G01 I A
- Issued
- Mar 5, 2018
- Abate by
- Mar 29, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening whwere they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910: a) West Shop: On November 6, 2017 and at times prior, the employer failed to maintain the minimum clearance around the electrical panel.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 F06 II
- Issued
- Mar 5, 2018
- Abate by
- Mar 29, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical: a) Detail Area: On November 6, 2017 and at times prior, employees were exposed to; Diethylene glycol monobutyl ether (Purple Power); Potassium hydroxide, Ethylene glycol monobutyl ether, Isopropyl alcohol, Ethanolamine, Sodium silicate (Dynamo X) while using these chemicals in various phases of the detailing process. The employer failed to ensure that each container of hazardous chemicals in the workplace was labeled with the product identifier and words, pictures, symbols, or combination thereof, which provides at least general information regarding the hazards of the chemicals.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Mac'S Frontierland, INC.
View Mac'S Frontierland, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 441110)
More inspections in MT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342754322.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.