Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BIRD HOME IMPROVEMENT, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of BIRD HOME IMPROVEMENT, INC. in (LOT #72) CANTERBURY WAY, ATLANTA, GA 30349 (NAICS 238170). OSHA activity number 342754835.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Bird Home Improvement, INC. — free Get an email when a new federal OSHA severe-injury report for Bird Home Improvement, INC. is published. One employer, no account, unsubscribe in one click.
Site address
(LOT #72) CANTERBURY WAY
City
ATLANTA
State
GA
ZIP
30349
Mailing
P.O. BOX 81893, CONYERS, GA 30013
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
6
Ownership type
A

4 citations on file for this inspection.

1926.102 A01

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 17, 2017
Penalty
Initial $2,173 · Current $2,173
29 CFR 1926.102(a)(1): Employees were not provided with eye and face protection equipment when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:  (a) New residential construction on Lot #72, Front side: On or about 11/03/2017 and at times prior, the employer exposed employees to struck-by hazards, in that protective eyewear was not provided to employees operating circular saws and pneumatic nail guns while engaged in siding installation.
Recent events (1)
  • — Z (S) $2173

1926.451 G01 VII

Serious Gravity 5 2 instances 2 exposed
Issued
Nov 17, 2017
Penalty
Initial $2,716 · Current $2,716
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section:  (a) New residential construction located on Lot #72, Front side: On or about 11/03/2017, and at times prior, the employer exposed employees to fall hazards of 10-feet, 10-inches to the lower level, in that a fall protection system was not provided to employees installing siding on a pump jack scaffold system.   (b) New residential construction located on Lot #72, Back side: On or about 11/03/2017, and at times prior, the employer exposed employees to fall hazards of 13-feet, 9-inches to the lower level, in that a fall protection system was not provided to employees installing siding on a pump jack scaffold system.
Recent events (1)
  • — Z (S) $2716

1926.1053 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 17, 2017
Penalty
Initial $2,173 · Current $2,173
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:  (a) New residential construction located on Lot #72, Front side: On or about 11/03/2017, and at times prior, the employer exposed employees to fall hazards of 11-feet to the lower level, in that the ladder used to access the roof was not extended at least 3-feet above the landing or secured to the structure.
Recent events (1)
  • — Z (S) $2173

1926.501 B13

Repeat Gravity 5 1 instance 1 exposed
Issued
Nov 17, 2017
Penalty
Initial $5,432 · Current $5,432
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:   (a) New residential construction located on Lot #72, Roof: On or about 11/03/2017, and at times prior, the employer exposed employees to fall hazards of 11-feet, 1-inch while working from a 5/12 pitched roof, in that a fall protection system was not provided to an employee installing siding using the roof as a walking/working surface.  Bird Home Improvement, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29 CFR 1926.501(b)(13), which was contained in OSHA inspection number 1259456, citation number 1, item number 1 and was affirmed as a final order on 10/27/2017, with respect to a workplace located at 433 Gage Hill Lane, Lexington Park Subdivision (Lot 31) Fairburn, GA 30213.
Recent events (1)
  • — Z (R) $5432

View Bird Home Improvement, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342754835.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.