Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ARVIN HOME IMPROVEMENTS, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ARVIN HOME IMPROVEMENTS, LLC in 4881 COOPER RD., BLUE ASH, OH 45242 (NAICS 238160). OSHA activity number 342754959.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Arvin Home Improvements, LLC — free Get an email when a new federal OSHA severe-injury report for Arvin Home Improvements, LLC is published. One employer, no account, unsubscribe in one click.
Site address
4881 COOPER RD.
City
BLUE ASH
State
OH
ZIP
45242
Mailing
324 TODD PL., HAMILTON, OH 45011
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

2 citations on file for this inspection.

1926.20 B02

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 5, 2017
Abate by
Jan 24, 2018
Penalty
Initial $3,803 · Current $2,282 Reduced
29 CFR 1926.20(b)(2): Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.    On November 6, 2017, located on the south side of a commercial roof structure, employees were observed installing flashing onto the exterior structure as there were no frequent and regular inspections being performed by a competent person to ensure the job-site, materials and equipment such as a fall protection systems and/or devices were being maintained and utilized in a safe condition.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (S) $2281.8
  • — Z (S) $3803

1926.501 B11

Serious Gravity 10 1 instance 3 exposed
Issued
Dec 5, 2017
Penalty
Initial $3,803 · Current $0 Reduced
29 CFR 1926.501(b)(11): "Steep roofs." Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels shall be protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems.    On November 6, 2017 located on the south side of a steep pitch commercial roof, employees were exposed to a fall hazard while installing metal flashing to commercial exterior structure wearing their harness that was not attached to the rope and anchor system. Potential fall height measured to be 20-7. Roof pitch was measured to be 5/12.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3803

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342754959.