Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S. AIR FORCE 62ND AIRLIFT WING, ACCESSORIES FLIGHT, ELECTRICAL-ENVIRONMENTAL

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of U.S. AIR FORCE 62ND AIRLIFT WING, ACCESSORIES FLIGHT, ELECTRICAL-ENVIRONMENTAL in BUILDING 1119, JOINT BASE LEWIS MCCHORD, WA 98438 (NAICS 488190). OSHA activity number 342760659.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. AIR Force 62ND Airlift Wing, Accessories Flight, Electrical-Environmental — free Get an email when a new federal OSHA severe-injury report for U.S. AIR Force 62ND Airlift Wing, Accessories Flight, Electrical-Environmental is published. One employer, no account, unsubscribe in one click.
Site address
BUILDING 1119
City
JOINT BASE LEWIS MCCHORD
State
WA
ZIP
98438
Mailing
100 COL JOE JACKSON BLVD, SUITE 1071, JOINT BASE LEWIS MCCHORD, WA 98438
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
488190
Employees
3
Ownership type
D

2 citations on file for this inspection.

1910.141 A03 I

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Jan 31, 2018
Abate by
Mar 7, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.141(a)(3)(i): Places of employment were not kept clean to the extent that the nature of the work allowed:    a)  General Shop, Room 102;  The soldering workbench tested positive for surface lead contamination. This exposes employees to lead ingestion hazards.   *Please note that surfaces (other than glass or metal) are porous and gritty scrubbing cleaners (examples are Soft Scrub, Comet or Ajax) are sometimes needed to fully decontaminate the area from surface lead contamination.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.145 C02 I

Deleted Serious Gravity 5 1 instance 3 exposed
Issued
Jan 31, 2018
Abate by
Mar 7, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.145(c)(2)(i): Caution signs were not used to warn against potential hazards or to caution against unsafe practices:  a)  General Shop, Room 102;  Caution signs were not posted to alert employees of the presence of lead and the precautions to take while performing tasks associated with soldering with lead containing solder.  This exposes employees to potential lead ingestion hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342760659.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.