Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S. AIR FORCE 446TH AIRLIFT WING

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of U.S. AIR FORCE 446TH AIRLIFT WING in BUILDING 745, JOINT BASE LEWIS MCCHORD, WA 98438 (NAICS 336413). OSHA activity number 342763471.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. AIR Force 446TH Airlift Wing — free Get an email when a new federal OSHA severe-injury report for U.S. AIR Force 446TH Airlift Wing is published. One employer, no account, unsubscribe in one click.
Site address
BUILDING 745
City
JOINT BASE LEWIS MCCHORD
State
WA
ZIP
98438
Mailing
1205 12TH STREET NE ROOM 125 BUILDING 1214, JOINT BASE LEWIS MCCHORD, WA 98438
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336413
Employees
232
Ownership type
D

2 citations on file for this inspection.

1910.107 B09

Serious Gravity 5 4 instances 1 exposed
Issued
Dec 6, 2017
Abate by
Jan 10, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.107(b)(9): A clear space of not less than 3 feet was not kept free from storage on all sides of paint booth(s):  a)  Building 745, Large Paint Booth, Room 111;  Three lockers for employee clothing/ PPE storage were located inside the large paint booth along the wall.   b)  Building 745, Large Paint Booth, Room 111;  A Pacer Industrial Mixer paint shaker was bolted to the floor inside the large paint booth along the wall.   c)  Building 745, Large Paint Booth, Room 111;  One locker for employee clothing/ PPE storage and a spill kit metal locker were located along the wall outside of the large paint booth. CORRECTED DURING INSPECTION  d)  Building 745, Small Paint Booth, Room 110;  One set of lockers for employee clothing/ PPE was located outside the small paint booth. CORRECTED DURING INSPECTION
Recent events (1)
  • — Z (S) $0

1910.107 E02

Serious Gravity 5 2 instances 1 exposed
Issued
Dec 6, 2017
Abate by
Jan 10, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.107(e)(2): The quantity of flammable or combustible liquids kept in the vicinity of spraying operations were not at a minimum required for operations or they exceeded a supply for one day or one shift:  a)  Building 745, Large Paint Booth, Room 111;  Dip tanks containing Deoxidine and Alodine were used and stored in the paint booth.  b)  Building 745, Large Paint Booth, Room 111;  A 55 gallon drum of flammable paint waste and thinner waste was stored in the paint booth.    This exposes employees to potential fire hazards.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342763471.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.