SHENANDOAH, PA —
OSHA Inspection: ATEECO INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ATEECO INC. in 600 EAST CENTRE ST., SHENANDOAH, PA 17976 (NAICS 311412). OSHA activity number 342764909.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ATEECO INC.
- Site address
- 600 EAST CENTRE ST.
- City
- SHENANDOAH
- State
- PA
- ZIP
- 17976
- Mailing
- PO BOX 606, SHENANDOAH, PA 17976
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 311412
- Employees
- 200
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.212 A01
- Issued
- Dec 29, 2017
- Penalty
- Initial $3,667 · Current $2,750 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) ABC Production Lines: The return belts located at the top of the A & B Graybill forming machines were not properly guarded to protect the operator and other employees in the area from contact with the ingoing nip points, as observed on or about November 9, 2017. Abatement Observed During Inspection.
Recent events (2)
- — I (S) $2750.25
- — Z (S) $3667
1910.219 F03
- Issued
- Dec 29, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(f)(3): Sprocket wheels and chains which were seven -7 feet or less above floors or platforms were not enclosed: a) ABC Production Lines: The chain and sprocket on the C forming machine was not completely enclosed by the surrounding wire mesh guard, as observed on or about November 9, 2017.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 I02
- Issued
- Dec 29, 2017
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(i)(2): Revolving surfaces of shaft coupling(s) were not covered by a safety sleeve: a) K Production Lines: The revolving shaft coupling located on the rear blanching conveyor was not covered, as observed on or about November 9, 2017. Abatement Observed During Inspection.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C06 II
- Issued
- Dec 29, 2017
- Abate by
- Feb 16, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: a) Maintenance and Sanitation: The employer did not certify that periodic inspections of the energy control procedures had been performed, on or about November 9, 2017. Abatement Certification Required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Ateeco INC.
View Ateeco INC.'s full OSHA safety record →
More inspections in this industry (NAICS 311412)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342764909.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.