Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S. DEPARTMENT OF THE INTERIOR

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of U.S. DEPARTMENT OF THE INTERIOR in P.O. BOX 1969, MANTEO, NC 27954 (NAICS 924120). OSHA activity number 342766235.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Department of the Interior — free Get an email when a new federal OSHA severe-injury report for U.S. Department of the Interior is published. One employer, no account, unsubscribe in one click.
Site address
P.O. BOX 1969
City
MANTEO
State
NC
ZIP
27954
Mailing
P.O. BOX 1969, MANTEO, NC 27954
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
924120
Employees
30000
Ownership type
D

7 citations on file for this inspection.

1910.213 H01

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.213(h)(1): The sides of the lower exposed portion of the blade of radial saw(s) were not guarded to the full diameter of the blade by a device that automatically adjusted itself to the thickness of the stock and remained in contact with the stock being cut:   U.S. Fish and Wildlife Service, Alligator River NWR:  Employees were exposed to amputation hazards due to unguarded lower portion of Delta radial arm saw.
Recent events (1)
  • — Z (S) $0

1910.213 H04

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.213(h)(4): Radial saw(s) were not installed in a manner so as to cause the cutting head to return gently to the starting position when released by the operator:   U.S. Fish and Wildlife Service, Alligator River NWR:  When the arm of the Delta radial arm saw was fully extended, it did not return to the starting position when released.
Recent events (1)
  • — Z (S) $0

1910.213 I01

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.213(i)(1): All portions of the saw blade were not enclosed or guarded as required:   U.S. Fish and Wildlife Service, Alligator River NWR:  The Delta band saw had no guard installed for the lower exposed portion of the blade, exposing employees to amputation hazards.
Recent events (1)
  • — Z (S) $0

1910.215 B09

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:   U.S. Fish and Wildlife Service, Alligator River NWR:  On or about November 10, 2017, the tongue guard adjustment on a Wilton 8 inch bench grinder was missing.
Recent events (1)
  • — Z (S) $0

1910.253 B02 II

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, or gangways where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons:     U.S. Fish and Wildlife Service, Alligator River NWR:  On or about November 10, 2017, oxygen and acetylene cylinders were stored free standing unsecured in the maintenance area and were subject to being knocked over by employees.
Recent events (1)
  • — Z (S) $0

1910.303 B02

Serious Gravity 1 1 instance 1 exposed
Issued
Nov 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:   U.S. Fish and Wildlife Service, Alligator River NWR:  On or about November 10, 2017, an electrical power tap or power strip was being used in lieu of fixed wiring to provide electrical power to a microwaves.
Recent events (1)
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 10 1 instance 1 exposed
Issued
Nov 14, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    U.S. Fish and Wildlife Service, Alligator River NWR: 240v electrical panel was missing an knockout on the right side panel.