DELAWARE, OH —
OSHA Inspection: SKY CLIMBER, LLC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of SKY CLIMBER, LLC. in 1800 PITTSBURG DRIVE + 1600 PITTSBURG DRIVE, DELAWARE, OH 43015 (NAICS 332323). OSHA activity number 342768041.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SKY CLIMBER, LLC.
- Site address
- 1800 PITTSBURG DRIVE + 1600 PITTSBURG DRIVE
- City
- DELAWARE
- State
- OH
- ZIP
- 43015
- Mailing
- 1800 PITTSBURG DRIVE, DELAWARE, OH 43015
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332323
- Employees
- 52
- Ownership type
- A
Citations
13 citations on file for this inspection.
1910.212 A01
- Issued
- Apr 12, 2018
- Abate by
- May 17, 2018
- Penalty
- Initial $7,391 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. Examples of guarding methods are-barrier guards, two-hand tripping devices,electronic safety devices, etc. a. On or about 01/26/2018 in the Fabrication Area, employees were exposed to flying chips while operating the Imco Mill. The Imco Mill did not have a chip guard in place to protect employees from flying chips while steel and aluminum milling operations were performed.
Recent events (3)
- — F (S) $0
- — C (S) $7391
- — Z (S) $7391
1910.212 A03 II
- Issued
- Apr 12, 2018
- Abate by
- Jul 17, 2019
- Penalty
- Initial $9,239 · Current $4,620 Reduced
General-duty citation text
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle. a. On or about 02/14/2018 in the Fabrication Area, employees were exposed to amputation hazards while operating the Atlantic Press Brake. There was no guarding in place to protect the employees' hands during bending operations.
Recent events (3)
- — F (S) $4620
- — C (S) $9239
- — Z (S) $9239
1910.212 B
- Issued
- Apr 12, 2018
- Penalty
- Initial $7,391 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(b): Anchoring fixed machinery. Machines designed for a fixed location shall be securely anchored to prevent walking or moving. a. On or about 11/14/2017 in the Welding Shop, employees were exposed to an Ultra-Tow Crane that was not securely anchored to the welding table it was sitting on. The crane was being held in place by a c-clamp. b. On or about 11/14/2017 in the Welding Shop, employees were exposed to a Strongway Crane that was not securely anchored to the welding table it was sitting on. The crane was being held in place by two c-clamps.
Recent events (3)
- — F (S) $0
- — C (S) $7391
- — Z (S) $7391
1910.215 A04
- Issued
- Apr 12, 2018
- Penalty
- Initial $9,239 · Current $0 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rests. On offhand grinding machines, work rests shall be used to support the work. They shall be of rigid construction and designed to be adjustable to compensate for wheel wear. Work rests shall be kept adjusted closely to the wheel with a maximum opening of one-eighth inch to prevent the work from being jammed between the wheel and the rest, which may cause wheel breakage. The work rest shall be securely clamped after each adjustment. The adjustment shall not be made with the wheel in motion. a. On or about 11/14/2017 in the Welding Shop, employees were exposed to a Baldor Bench Grinder with an improperly adjusted work rest. The work rest was approximately 7/16 of an inch from the face of the grinding wheel. b. On or about 11/14/2017 in the Fabrication Area, employees were exposed to a Central Machinery Bench Grinder with an improperly adjusted work rest. The work rest was approximately 3/8 of an inch from the face of the grinding wheel.
Recent events (3)
- — F (O) $0
- — C (S) $9239
- — Z (S) $9239
1910.215 B09
- Issued
- Apr 12, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): Exposure adjustment. Safety guards of the types described in Subparagraphs (3) and (4) of this paragraph, where the operator stands in front of the opening, shall be constructed so that the peripheral protecting member can be adjusted to the constantly decreasing diameter of the wheel. The maximum angular exposure above the horizontal plane of the wheel spindle as specified in paragraphs (b)(3) and (4) of this section shall never be exceeded, and the distance between the wheel periphery and the adjustable tongue or the end of the peripheral member at the top shall never exceed one-fourth inch. (See Figures O-18, O-19, O-20, O-21, O-22, and O-23.) a. On or about 11/14/2017 in the Welding Shop, employees were exposed to a Baldor Bench Grinder that had its tongue guard removed. The gap created by the missing tongue guard was approximately 1.25 inches above the wheel periphery. b. On or about 11/14/2017 in the Fabrication Area, employees were exposed to a Central Machinery Bench Grinder that had its tongue guard removed. The gap created by the missing tongue guard was approximately 1.20 inches above the wheel periphery.
Recent events (3)
- — F (O) $0
- — C (S) $0
- — Z (S) $0
1910.219 C04 I
- Issued
- Apr 12, 2018
- Penalty
- Initial $7,391 · Current $0 Reduced
General-duty citation text
29 CFR 1910.219(c)(4)(i): Projecting shaft ends shall present a smooth edge and end and shall not project more than one-half the diameter of the shaft unless guarded by nonrotating caps or safety sleeves. a. On or about 01/26/2018 in the Fabrication Area, employees were exposed to an unguarded rotating shaft while performing sanding operations on the Jet Belt & Disc Sander. The rotating shaft was 1/2 inch in diameter and projected approximately 1 inch from the machine's body.
Recent events (3)
- — F (S) $0
- — C (S) $7391
- — Z (S) $7391
1910.219 C04 II
- Issued
- Apr 12, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(c)(4)(ii): Unused keyways shall be filled up or covered. a. On or about 01/26/2018 in the Fabrication Area, employees performing sanding operations were exposed to an unused keyway on the rotating shaft of the Jet Belt & Disc Sander. The unused keyway was approximately 1/2 inch long and was not guarded or filled.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.219 D01
- Issued
- Apr 12, 2018
- Penalty
- Initial $9,239 · Current $0 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Guarding. Pulleys, any parts of which are seven (7) feet or less from the floor or working platform, shall be guarded in accordance with the standards specified in paragraphs (m) and (o) of this section. Pulleys serving as balance wheels (e.g., punch presses) on which the point of contact between belt and pulley is more than six feet six inches (6 ft. 6 in.) from the floor or platform may be guarded with a disk covering the spokes. a. On or about 01/26/2018 in the Fabrication Area, employees were exposed to two rotating pulleys while operating the Imco Mill. One of the guards on the Imco Mill's head, that was designed to cover the rotating pulleys, had been removed.
Recent events (3)
- — F (S) $0
- — C (S) $9239
- — Z (S) $9239
1910.219 E01 I
- Issued
- Apr 12, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(1)(i): Where both runs of horizontal belts are seven (7) feet or less from the floor level, the guard shall extend to at least fifteen (15) inches above the belt or to a standard height, except that where both runs of a horizontal belt are 42 inches or less from the floor, the belt shall be fully enclosed in accordance with paragraphs (m) and (o) of this section. a. On or about 01/26/2018 in the Fabrication Area, employees were exposed to a rotating belt five feet from the floor while operating the Imco Mill. One of the guards on the Imco Mill's head, that was designed to cover the rotating belt, had been removed.
Recent events (3)
- — F (S) $0
- — C (S) $0
- — Z (S) $0
1910.303 B01 I
- Issued
- Apr 12, 2018
- Abate by
- Apr 24, 2018
- Penalty
- Initial $5,543 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(b)(1)(i): Suitability for installation and use in conformity with the provisions of this subpart; Note to paragraph (b)(1)(i) of this section: Suitability of equipment for an identified purpose may be evidenced by listing or labeling for that identified purpose. a. On or about 01/26/2018 in the Fabrication Area, a surge protector was used to provide power to a Central Machinery Bench Grinder and a Jet Belt & Disc Sander/Grinder. The surge protector was not listed and labeled to be used in an industrial setting.
Recent events (3)
- — F (S) $0
- — C (S) $5543
- — Z (S) $5543
1910.303 G02 I
- Issued
- Apr 12, 2018
- Penalty
- Initial $9,239 · Current $0 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the following means: a. On or about 11/14/2017 in the Assembly Line Area, employees were exposed to live electrical wires and terminals of a Woodhead 3000-Series Pendant Drop electrical outlet. The outlet was damaged causing the front cover to become separated from the box.
Recent events (3)
- — F (S) $0
- — C (S) $9239
- — Z (S) $9239
1910.305 J01 I
- Issued
- Apr 12, 2018
- Penalty
- Initial $12,934 · Current $6,467 Reduced
General-duty citation text
29 CFR 1910.305(j)(1)(i): Fixtures, lampholders, lamps, rosettes, and receptacles may have no live parts normally exposed to employee contact. However, rosettes and cleat-type lampholders and receptacles located at least 2.44 m (8.0 ft) above the floor may have exposed terminals. a. On or about 11/14/2017 in the Welding Shop, employees were exposed to electrical hazards from the two lampholders on the Baldor Bench Grinder that did not have bulbs installed. The two lampholders had exposed live sockets directly above where employees performed grinding on tungsten welding rods.
Recent events (3)
- — F (S) $6467
- — C (S) $12934
- — Z (S) $12934
1910.132 D02
- Issued
- Apr 12, 2018
- Abate by
- Jul 17, 2019
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment. a. At the workplace, on or about 03/28/2018, the employer's PPE hazard assessment was not written or certified.
Recent events (3)
- — F (O) $0
- — C (O) $0
- — Z (O) $0
More inspections at SKY Climber, LLC.
View SKY Climber, LLC.'s full OSHA safety record →
More inspections in this industry (NAICS 332323)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342768041.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.