Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ATLAS STEEL & SUPPLY, LLC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of ATLAS STEEL & SUPPLY, LLC. in 625 DEPOT ST, PARKERSBURG, WV 26101 (NAICS 331111). OSHA activity number 342768405.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Atlas Steel & Supply, LLC. — free Get an email when a new federal OSHA severe-injury report for Atlas Steel & Supply, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
625 DEPOT ST
City
PARKERSBURG
State
WV
ZIP
26101
Mailing
625 DEPOT ST, PARKERSBURG, WV 26101
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331111
Employees
6
Ownership type
A

10 citations on file for this inspection.

1910.22 A02

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 6, 2018
Abate by
Mar 30, 2018
Penalty
Initial $1,413 · Current $1,200 Reduced
29 CFR 1910.22(a)(2): The Floor of each workroom was not maintained in a clean and, to the extent feasible, in a dry condition:    a.)  Warehouse:  On or about 11/14/17, the floor of the work area was not maintained dry due to a leaking roof.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1413

1910.29 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 6, 2018
Abate by
Mar 30, 2018
Penalty
Initial $1,885 · Current $1,600 Reduced
29 CFR 1910.29(b)(1): The top edge height of top rails, or equivalent guardrail system members, were not 42 inches, plus or minus 3 inches, above the walking-working surface:    a.)  Warehouse:  On or about 11/14/17, the platform at the top of the stairs leading to the emergency exit which was 49" above the ground, had a top rail that was measured to be 37" high.
Recent events (2)
  • — I (S) $1600
  • — Z (S) $1885

1910.29 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 6, 2018
Abate by
Mar 30, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.29(b)(2): The employer did not ensure that midrails, screens, mesh, intermediate vertical members, solid panels, or equivalent intermediate members are installed between the walking-working surface and the top edge of the guardrail system as follows when there is not a wall or parapet that is at least 21 inches (53 cm) high:  a.)  Warehouse:  On or about 11/14/17, the platform at the top of the stairs leading to the emergency exit which was 49" above the ground, had no midrail.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.36 D01

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 6, 2018
Abate by
Mar 30, 2018
Penalty
Initial $1,413 · Current $1,200 Reduced
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:    a.)  Warehouse:  On or about 11/14/17, the designated emergency exit door was locked with a slide bolt.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1413

1910.37 B02

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 6, 2018
Abate by
Mar 30, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit":  a.)  Warehouse:  On or about 11/14/17, the designated emergency exit was not properly labeled.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 C04

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 6, 2018
Abate by
Mar 30, 2018
Penalty
Initial $1,413 · Current $1,200 Reduced
29 CFR 1910.157(c)(4): Portable fire extinguishers were not maintained in a fully charged and operable condition:    a.)  Warehouse:  On or about 11/14/17, fire extinguishers located in the warehouse were not maintained in an operable condition.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1413

1910.157 E03

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 6, 2018
Abate by
Mar 30, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:  a.)  Warehouse:  On or about 11/14/17, ABC fire extinguishers had not received an annual maintenance check since January 2016.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 G01

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 6, 2018
Abate by
Mar 30, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting:  a.)  Warehouse:  On or about 11/14/17, employees on site expected to fight incipient stage fires were not provided with an education program on the hazards involved.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 6, 2018
Abate by
Mar 30, 2018
Penalty
Initial $1,885 · Current $1,600 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    a.)  Warehouse:  On or about 11/14/17, the 480 volt panel box had a missing breaker exposing the 240 volt busbar.
Recent events (2)
  • — I (S) $1600
  • — Z (S) $1885

1910.305 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 6, 2018
Abate by
Mar 30, 2018
Penalty
Initial $2,356 · Current $0 Reduced
29 CFR 1910.305(e)(1): Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations were not installed to prevent moisture or water from entering and accumulating within the enclosures:    a.)  Warehouse:  On or about 11/14/17, a plastic tarp was placed overtop of the 480 volt panel box to prevent the water from entering the panel box.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2356

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342768405.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.