Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HEITKAMP MASONRY INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of HEITKAMP MASONRY INC. in 5100 MANCHESTER AVENUE, SAINT LOUIS, MO 63110 (NAICS 238140). OSHA activity number 342769890.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Heitkamp Masonry INC. — free Get an email when a new federal OSHA severe-injury report for Heitkamp Masonry INC. is published. One employer, no account, unsubscribe in one click.
Site address
5100 MANCHESTER AVENUE
City
SAINT LOUIS
State
MO
ZIP
63110
Mailing
16129 WESWOODS BUSINESS PARK, ELLISVILLE, MO 63021
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
200
Ownership type
A

2 citations on file for this inspection.

1926.706 A

Deleted Serious Gravity 5 8 instances 5 exposed
Issued
Nov 16, 2017
Abate by
Nov 29, 2017
Penalty
Initial $6,926 · Current $0 Reduced
29 CFR 1926.706(a): A limited access zone was not established whenever a masonry wall was being constructed:  At 5100 Manchester Avenue, St. Louis, MO, a limited access zone had not been established along all four masonry walls.  The height of each wall was approximately 16'9".  This violation was noted on 11/14/17.
Recent events (2)
  • — I (S) $0
  • — Z (S) $6926

1926.706 B

Deleted Serious Gravity 5 7 instances 5 exposed
Issued
Nov 16, 2017
Abate by
Nov 29, 2017
Penalty
Initial $0 · Current $0
29 CFR 1926.706(b): Masonry walls over eight feet in height were not adequately braced to prevent overturning and to prevent collapse until permanent supporting elements of the structure were in place:  At 5100 Manchester Avenue, St. Louis, MO, the four masonry walls belonging to a structure under construction were not braced to prevent an unplanned collapse.  The height of each wall was approximately 16'9".  This violation was observed on 11/14/17.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Heitkamp Masonry INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342769890.