Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: G-TEKT NORTH AMERICA CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of G-TEKT NORTH AMERICA CORPORATION in 6700 STATE ROUTE 29 N.E., WEST JEFFERSON, OH 43162 (NAICS 336111). OSHA activity number 342769940.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch G-Tekt North America Corporation — free Get an email when a new federal OSHA severe-injury report for G-Tekt North America Corporation is published. One employer, no account, unsubscribe in one click.
Site address
6700 STATE ROUTE 29 N.E.
City
WEST JEFFERSON
State
OH
ZIP
43162
Mailing
6700 STATE ROUTE 29 N.E., WEST JEFFERSON, OH 43162
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336111
Employees
79
Ownership type
A

5 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 5 1 instance 20 exposed
Issued
Jan 9, 2018
Abate by
Mar 5, 2018
Penalty
Initial $8,315 · Current $8,315
29 CFR 1910.147(c)(4)(ii): The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:  a. On or about November 14, 2017, and at times prior thereto, employees were performing service and maintenance covered activities in the robot cells and inside the laser enclosures, such as, but not limited to, cleaning, adjustments, replacing nozzles, and replacing lenses. The employer did not develop and implement specific energy control procedures for authorized employees to utilize to isolate and control each hazardous energy source, such as, but not limited to, lockout point locations, lockout devices to operate, and removal of residual and/or stored energy.
Recent events (2)
  • — I (S) $8315
  • — Z (S) $8315

1910.147 C07 I A

Serious Gravity 10 1 instance 20 exposed
Issued
Jan 9, 2018
Abate by
Mar 5, 2018
Penalty
Initial $11,641 · Current $11,641
29 CFR 1910.147(c)(7)(i)(A): Each authorized employee shall receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.   a. On or about November 14, 2017, and at times prior thereto, employees performing service and maintenance covered activities in the robot cells and inside the laser enclosures were not provided with authorized lockout/tagout training.
Recent events (2)
  • — I (S) $11641
  • — Z (S) $11641

1910.147 C07 I B

Serious Gravity 10 1 instance 50 exposed
Issued
Jan 9, 2018
Abate by
Mar 5, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i)(B): Each affected employee shall be instructed in the purpose and use of the energy control procedure.  a. On or about November 14, 2017, and at times prior thereto, employees were working near service and maintenance activities being performed without receiving affected lockout/tagout training.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D03

Serious Gravity 5 1 instance 79 exposed
Issued
Jan 9, 2018
Abate by
Mar 5, 2018
Penalty
Initial $8,315 · Current $8,315
29 CFR 1910.147(d)(3): Machine or equipment isolation. All energy isolating devices that are needed to control the energy to the machine or equipment shall be physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s).   a. On or about November 14, 2017, and at times prior thereto, employees were performing service and maintenance covered activities in the robot cells on Lasers 3 & 4 and inside the Laser 1 through 8, laser enclosures, such as, but not limited to, cleaning, adjustments, replacing nozzles, and replacing lenses. The employer did not ensure that employees isolated and affixed a lockout device to the hazardous energy sources prior to permitting them to perform the covered activities in order to ensure each employee performing the work had control over their own safety. The safety interlock plugs remained hanging outside the guarded areas while employees performed the work.
Recent events (2)
  • — I (S) $8315
  • — Z (S) $8315

1910.178 P01

Serious Gravity 5 1 instance 79 exposed
Issued
Jan 9, 2018
Penalty
Initial $8,315 · Current $8,315
29 CFR 1910.178(p)(1): If at any time a powered industrial truck is found to be in need of repair, defective, or in any way unsafe, the truck shall be taken out of service until it has been restored to safe operating condition.   a. On or about November 14, 2017, employees were operating a Toyota, serial number 10328, propane powered forklift with a hydraulic leak. The condition of the forklift exposed employees to a crushed by hazard.
Recent events (2)
  • — I (S) $8315
  • — Z (S) $8315

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342769940.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.