Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: NAIRN CONCRETE SERVICES, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of NAIRN CONCRETE SERVICES, INC. in 102 BURMASTER ST., BELLE CHASSE, LA 70037 (NAICS 327320). OSHA activity number 342774049.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Nairn Concrete Services, INC. — free Get an email when a new federal OSHA severe-injury report for Nairn Concrete Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
102 BURMASTER ST.
City
BELLE CHASSE
State
LA
ZIP
70037
Mailing
102 BURMASTER ST., BELLE CHASSE, LA 70037
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327320
Employees
26
Ownership type
A

9 citations on file for this inspection.

1910.134 C01

Serious Gravity 1 1 instance 1 exposed
Issued
Dec 14, 2017
Abate by
Dec 29, 2017
Penalty
Initial $3,802 · Current $1,521 Reduced
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:    On or about November 16, 2017, in the shop area, the employer allowed employees to use a 3M P100 Half-face Respirator without a Respiratory Protection Program.
Recent events (2)
  • — I (S) $1520.8
  • — Z (S) $3802

1910.134 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Dec 14, 2017
Abate by
Dec 29, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  On or about November 16, 2017, in the shop area, the employer allowed employees to use a 3M P100 Half Face-piece Respirator without a medical evaluation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 F01

Serious Gravity 1 1 instance 1 exposed
Issued
Dec 14, 2017
Abate by
Dec 29, 2017
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT):  On or about November 16, 2017, in the shop area, the employer allowed employees to use a 3M P100 Half Face-piece Respirator without fit testing to ensure a proper fit.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.146 D03

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 14, 2017
Abate by
Dec 29, 2017
Penalty
Initial $6,338 · Current $2,535 Reduced
29 CFR 1910.146(d)(3): Under the permit-required confined space program required by 29 CFR 1910.146(c)(4), the employer did not develop and implement the means, procedures, and practices necessary for safe permit space entry operations:    On or about November 16, 2017, the employer did not assure the permit required confined program was implemented prior to employees entering the permit required confined space of the drum of the cement trucks.
Recent events (2)
  • — I (S) $2535.2
  • — Z (S) $6338

1910.147 C04 II B

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 14, 2017
Abate by
Dec 29, 2017
Penalty
Initial $5,070 · Current $2,028 Reduced
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy:    On or about November 16, 2017, the employer did not ensure that the energy control procedures addressed all potential hazardous energy sources for employees who were performing the task of chipping inside the drum of a cement truck.
Recent events (2)
  • — I (S) $2028
  • — Z (S) $5070

1910.157 E03

Serious Gravity 1 5 instances 15 exposed
Issued
Dec 14, 2017
Abate by
Dec 29, 2017
Penalty
Initial $3,802 · Current $1,521 Reduced
29 CFR 1910.157(e)(3): The date of the annual maintenance check of portable fire extinguishers was not recorded:    On or about November 16, 2017, where employees are required to fight incipient level fires, portable fire extinguishers were not subject to an annual maintenance check located outside of break trailer and shop area.
Recent events (2)
  • — I (S) $1520.8
  • — Z (S) $3802

1910.212 A01

Deleted Serious Gravity 1 1 instance 2 exposed
Issued
Dec 14, 2017
Abate by
Dec 29, 2017
Penalty
Initial $3,802 · Current $0 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  On or about November 16, 2017, in the shop area, employees used a Jet Bandsaw (Serial # 7010), which was missing its guard, to cut brake line shafts and other production tasks.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3802

1910.253 B02 IV

Serious Gravity 5 3 instances 2 exposed
Issued
Dec 14, 2017
Abate by
Dec 29, 2017
Penalty
Initial $5,070 · Current $2,028 Reduced
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use:    On or about November 16, 2017, in the shop area, the employer allowed employees to store cylinders uncapped and equipped with regulators while they were not in use.
Recent events (2)
  • — I (S) $2028
  • — Z (S) $5070

1910.253 B04 III

Other-than-serious 1 instance 15 exposed
Issued
Dec 14, 2017
Abate by
Dec 29, 2017
Penalty
Initial $8,873 · Current $1,000 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet:    On or about November 16, 2017, in the northeast corner of the shop area, employees worked around a compressed gas cylinder of acetylene which was stored with four compressed gas cylinders of oxygen in the cylinder storage area.
Recent events (2)
  • — I (O) $1000
  • — Z (S) $8873

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342774049.