OSHA Inspection: KERSTETTER HOME IMPROVEMENTS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of KERSTETTER HOME IMPROVEMENTS in 206 PINE STREET, STEELTON, PA 17113 (NAICS 238160). OSHA activity number 342778966.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kerstetter Home Improvements for free Get an email when a new federal OSHA severe-injury report for Kerstetter Home Improvements is published. One employer, no account, unsubscribe in one click.
Site address
206 PINE STREET
City
STEELTON
State
PA
ZIP
17113
Mailing
331 BUNKER HILL ROAD, HALIFAX, PA 17032
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
2
Ownership type
Private (A)

2 citations on file for this inspection.

1926.501 B13

Other-than-serious 1 instance 2 exposed
Issued
Dec 5, 2017
Penalty
Initial $3,803 · Current $1,000 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system:    (a) 206 Pine Street, Steelton, PA - Employee(s) were observed performing roofing work activity on a 16 in 12 pitch residential roof without the benefit of a fall protection system, thereby exposing employees to a fall of approximately 9 feet to dormer valley between the two houses and 20 feet to the ground below, on or about November 16, 2017.         No abatement certification or documentation required.
Recent events (3)
  • · F (O) $1000
  • · C (S) $3803
  • · Z (S) $3803

1926.451 C02

Other-than-serious 1 instance 2 exposed
Issued
Dec 5, 2017
Penalty
Initial $1,630 · Current $0 Reduced
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation:    (a) 206 Pine Street, Steelton, PA - Employee(s) were observed using the scaffolding as access to the residential roof without the benefit of base plates, thereby exposing employees to injuries, on or about November 16, 2017.    No abatement certification or documentation required.
Recent events (3)
  • · F (O) $0
  • · C (S) $1630
  • · Z (S) $1630