Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: LITHIA CHEVROLET BUICK GMC OF HELENA

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of LITHIA CHEVROLET BUICK GMC OF HELENA in 1501 CEDAR ST., HELENA, MT 59601 (NAICS 811111). OSHA activity number 342782109.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Lithia Chevrolet Buick GMC of Helena — free Get an email when a new federal OSHA severe-injury report for Lithia Chevrolet Buick GMC of Helena is published. One employer, no account, unsubscribe in one click.
Site address
1501 CEDAR ST.
City
HELENA
State
MT
ZIP
59601
Mailing
1501 CEDAR ST., HELENA, MT 59601
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811111
Employees
60
Ownership type
A

7 citations on file for this inspection.

1910.106 D04 I

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 11, 2018
Abate by
Feb 7, 2018
Penalty
Initial $6,467 · Current $3,880 Reduced
29 CFR 1910.106(d)(4)(i): Opening(s) from inside flammable and combustible storage room(s) into other rooms or buildings were not provided with noncombustible liquid tight raised seal or ramp at least 4 inches in height. Opening(s) from inside flammable and combustible storage room(s) were not provided with approved self-closing fire doors. The inside flammable and combustible storage room was not liquid-tight where the walls joined the floor:  (a) Express Lane: On or about November 16, 2017 and at times prior, employees were exposed to fire hazards when methanol (Flash point 11.0 degrees Celsius), was stored in a room that would not contain these flammable liquids in the event of a spill.
Recent events (2)
  • — I (S) $3880.2
  • — Z (S) $6467

1910.106 E02 IV C

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 11, 2018
Abate by
Feb 7, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.106(e)(2)(iv)(c): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), were used where there are open flames or other sources of ignition within the possible path of vapor travel:  (a) Express Lane: On or about November 16, 2017 and at times prior, employees were exposed to fire and explosion hazards when methanol (Flash point 11.0 degrees Celsius), was stored directly below a non intrinsically safe electrical panel.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.106 E02 IV D

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 11, 2018
Abate by
Feb 7, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.106(e)(2)(iv)(d): Flammable liquids were not drawn from or transferred into vessels, containers, or portable tanks within a building only through a closed piping system, from safety cans, by means of a device drawing through the top, or from a container or portable tanks by gravity through an approved self-closing valve:  (a) Express Lane: On or about November 16, 2017 and at times prior, employees were exposed to fire and explosion hazards when methanol (Flash point 11.0 degrees Celsius), Category II flammable liquid was dispensed from metal 55 gallon drum into plastic containers that were not safety cans.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.106 E06 II

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 11, 2018
Abate by
Feb 7, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.106(e)(6)(ii): Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), were dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with:  (a) Express Lane: On or about November 16, 2017 and at times prior, employees were exposed to fire and explosion hazards when methanol (Flash point 11.0 degrees Celsius) a category II flammable liquid was dispensed without bonding the dispensing nozzle and accepting container.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.215 B09

Serious Gravity 5 1 instance 25 exposed
Issued
Jan 11, 2018
Abate by
Feb 7, 2018
Penalty
Initial $5,174 · Current $3,104 Reduced
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  (a) Shop: On or about November 16, 2017 and at times prior, employees were exposed to flying pieces in the event of an abrasive wheel fracture while using a Delta Bench Grinder with an unadjusted tongue guard.
Recent events (2)
  • — I (S) $3104.4
  • — Z (S) $5174

1910.242 B

Serious Gravity 1 3 instances 25 exposed
Issued
Jan 11, 2018
Abate by
Feb 7, 2018
Penalty
Initial $3,880 · Current $2,328 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  (a) Detail bay: On or about November 16, 2017 and at times prior, employees were exposed to flying pieces of dirt and metal while using air nozzles with 46.8 p.s.i. of unregulated air at the nozzle.     (b) #10 bay: On or about November 16, 2017 and at times prior, employees were exposed to flying pieces of dirt and metal while using air nozzles with 109 p.s.i. of unregulated air at the nozzle.   (a) #14 bay: On or about November 16, 2017 and at times prior, employees were exposed to flying pieces of dirt and metal while using air nozzles with 114 p.s.i. of unregulated air at the nozzle.
Recent events (2)
  • — I (S) $2328
  • — Z (S) $3880

1910.1200 F06 II

Serious Gravity 1 4 instances 30 exposed
Issued
Jan 11, 2018
Abate by
Feb 7, 2018
Penalty
Initial $3,880 · Current $2,328 Reduced
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical:  (a) Detail Bay: On or about November 16, 2017 and at times prior, employees were exposed to chemicals including, but not limited to, ethylene glycol (DEX 50/50) that was stored in a secondary container labeled ACDelco Diesel Fluid (DEF).                                                                                               (b) #7 Bay: On or about November 16, 2017 and at times prior, employees were exposed to ethylene glycol (Service Pro Concentrate Antifreeze and Coolant) that were stored in secondary containers marked in black ink Universal 50/50, Washer Fluid, DEX Cool 50/50 and a DEX Cool container with the identifier "WATER" marked on the side.
Recent events (2)
  • — I (S) $2328
  • — Z (S) $3880

View Lithia Chevrolet Buick GMC of Helena's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342782109.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.