Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SAVANNA ENERGY SERVICES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SAVANNA ENERGY SERVICES in 12..8 MILES SOUTH OF COYANOSA, TX SAVANNA RIG #650, COYANOSA, TX 79730 (NAICS 213111). OSHA activity number 342785730.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Savanna Energy Services — free Get an email when a new federal OSHA severe-injury report for Savanna Energy Services is published. One employer, no account, unsubscribe in one click.
Site address
12..8 MILES SOUTH OF COYANOSA, TX SAVANNA RIG #650
City
COYANOSA
State
TX
ZIP
79730
Mailing
P.O. BOX 14077, ODESSA, TX 79768
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213111
Employees
300
Ownership type
A

3 citations on file for this inspection.

1910.151 C

Serious Gravity 1 1 instance 2 exposed
Issued
Dec 13, 2017
Abate by
Jan 3, 2018
Penalty
Initial $5,432 · Current $5,432
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:  Rig Site $#650: On or about November 15, 2017, employees were working at the mixing area where there was an empty eye wash station and they had mixed corrosive chemicals. This exposed employees to health and/or eye irritation hazards.
Recent events (1)
  • — Z (S) $5432

1910.178 P01

Serious Gravity 5 1 instance 2 exposed
Issued
Dec 13, 2017
Abate by
Jan 10, 2018
Penalty
Initial $7,243 · Current $7,243
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been  taken out of service until restored to safe operating condition(s):  On or about November 15, 2017, employees were working on a rig site. They were using a rough terrain forklift that had a big windshield crack in the line of sight. This exposed employees to probable struck-by hazards.
Recent events (1)
  • — Z (S) $7243

1910.303 B02

Other-than-serious 2 instances 2 exposed
Issued
Dec 13, 2017
Abate by
Jan 3, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  Rig Site #650: On or about November 15, 2017, employees were working where there were two instances of listed or labeled electrical equipment:  1. They were using a fifty foot 12AWG three way extension cord to connect to two fifty foot 10AWG extension cords.  2. They were also using a power tap to plug in a microwave and a coffee pot.  These issues exposed employees to fire and/or burn hazards.
Recent events (1)
  • — Z (O) $0

View Savanna Energy Services's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342785730.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.