Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GANIERE POWER SYSTEMS INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GANIERE POWER SYSTEMS INC. in 720 WESLEY AVE STE 1, TARPON SPRINGS, FL 34689 (NAICS 333922). OSHA activity number 342785797.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ganiere Power Systems INC. — free Get an email when a new federal OSHA severe-injury report for Ganiere Power Systems INC. is published. One employer, no account, unsubscribe in one click.
Site address
720 WESLEY AVE STE 1
City
TARPON SPRINGS
State
FL
ZIP
34689
Mailing
720 WESLEY AVE STE 1, TARPON SPRINGS, FL 34689
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333922
Employees
4
Ownership type
A

2 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 8, 2018
Abate by
Jan 19, 2018
Penalty
Initial $2,772 · Current $2,772
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  a) Shop - A Milwaukee 14 inch saw was missing the lower blade guard, leaving the blade exposed, on or about November 21, 2017.
Recent events (1)
  • — Z (S) $2772

1910.22 D01

Other-than-serious 1 instance 4 exposed
Issued
Jan 8, 2018
Abate by
Feb 12, 2018
Penalty
Initial $0 · Current $0
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate.  a) Above Office - A mezzanine used to store materials was not marked for the approved load, on or about November 21, 2017.
Recent events (1)
  • — Z (O) $0

View Ganiere Power Systems INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342785797.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.