Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ROD GARCIA PAINTING

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of ROD GARCIA PAINTING in 1925 VINE ST., CINCINNATI, OH 45202 (NAICS 238320). OSHA activity number 342787009.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ROD Garcia Painting — free Get an email when a new federal OSHA severe-injury report for ROD Garcia Painting is published. One employer, no account, unsubscribe in one click.
Establishment
ROD GARCIA PAINTING
Site address
1925 VINE ST.
City
CINCINNATI
State
OH
ZIP
45202
Mailing
249 OAKMONT ST., CINCINNATI, OH 45216
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238320
Employees
4
Ownership type
A

2 citations on file for this inspection.

1926.501 B13

Deleted Serious Gravity 10 2 instances 2 exposed
Issued
Nov 29, 2017
Abate by
Dec 5, 2017
Penalty
Initial $3,803 · Current $0 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.   Located along central interior stairwell landings and interior floor areas of the 2nd, 3rd and 4th floors of the residential structure employee(s) were exposed to unprotected window wall openings without conventional fall protection and exposed to fall hazards in excess of 20 feet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3803

1926.503 A01

Deleted Serious Gravity 10 2 instances 2 exposed
Issued
Nov 29, 2017
Abate by
Jan 18, 2018
Penalty
Initial $3,803 · Current $0 Reduced
29 CFR 1926.503(a)(1): The employer shall provide a training program for each employee who might be exposed to fall hazards. The program shall enable each employee to recognize the hazards of falling and shall train each employee in the procedures to be followed in order to minimize these hazards.   Located along various areas of the residential structure employees were accessing or working adjacent to unprotected window wall openings in elevated positions in excess of 20 feet, who were not trained to recognize the hazards of falling and were not knowledgeable of the procedures to be followed to minimize those hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3803

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342787009.