MENTONE, TX —
OSHA Inspection: DEEPWELL EQUIPMENT RENTALS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DEEPWELL EQUIPMENT RENTALS in 11.27 MILES NORTHWEST OF WINK, TX CACTUS RIG #129, MENTONE, TX 79754 (NAICS 213112). OSHA activity number 342787868.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DEEPWELL EQUIPMENT RENTALS
- Site address
- 11.27 MILES NORTHWEST OF WINK, TX CACTUS RIG #129
- City
- MENTONE
- State
- TX
- ZIP
- 79754
- Mailing
- 459 INTERSTATE 20 W, PECOS, TX 79772
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213112
- Employees
- 15
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.303 B01 IV
- Issued
- Apr 6, 2018
- Abate by
- Apr 25, 2018
- Penalty
- Initial $2,217 · Current $1,330 Reduced
General-duty citation text
29 CFR 1910.303(b)(1)(iv): Electrical insulation was not free from recognized hazards that were likely to cause death or serious physical harm to employees: On or about November 16, 2017, a yellow 50 foot extension cord going to the sewage pump behind the safety trailer had some damage to its insulation. This exposed employees to electric shock hazards.
Recent events (2)
- — I (S) $1330.2
- — Z (S) $2217
1910.303 F02
- Issued
- Apr 6, 2018
- Abate by
- Apr 25, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident: On or about November 16, 2018, the Mud Engineer and Crew trailers' electrical panels were not labeled properly. This exposed employees to electric shock hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 A02 X
- Issued
- Apr 6, 2018
- Abate by
- Apr 25, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(a)(2)(x): Flexible cords and cables were not protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points: On or about November 16, 2018, the water pump going to the Mud Logger and Backyard trailer had a red extension cord which was run through the lid of a hard plastic box, the cord showed some indentation on the insulation. This exposed employees to electric shock hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 J02 V
- Issued
- Apr 6, 2018
- Abate by
- Apr 25, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(j)(2)(v): A receptacle installed outdoors in a location protected from the weather or in other damp locations did not have an enclosure for the receptacle that was weatherproof when the receptacle was covered (attachment plug cap not inserted and receptacle covers closed): On or about November 16, 2018, the Company man's trailer had a receptacle outlet missing its exterior cover at the back end. This exposed employees to electric shock and /or burn hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Deepwell Equipment Rentals
View Deepwell Equipment Rentals's full OSHA safety record →
More inspections in this industry (NAICS 213112)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342787868.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.