DALLAS, TX —
OSHA Inspection: ADOLPHUS HOTEL
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of ADOLPHUS HOTEL in 1321 COMMERCE STREET, DALLAS, TX 75202 (NAICS 721110). OSHA activity number 342791266.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ADOLPHUS HOTEL
- Site address
- 1321 COMMERCE STREET
- City
- DALLAS
- State
- TX
- ZIP
- 75202
- Mailing
- 1321 COMMERCE STREET, DALLAS, TX 75202
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 721110
- Employees
- 200
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.68 B08 I
- Issued
- Feb 23, 2018
- Abate by
- Mar 21, 2018
- Penalty
- Initial $11,641 · Current $3,900 Reduced
General-duty citation text
29 CFR 1910.68(b)(8)(i): The entrances and exits at all floor landings affording access to the man lift were not guarded by a maze (staggered railing) or a handrail equipped with self-closing gates: (a) On or about November 22, 2017, at a workplace located at 1321 Commerce Street, Dallas, TX 75202, employees using a Humphrey belt man lift, serial number S-4006, model number 14S GHC-3-RA where a gate or rail was not provided were exposed to a fall hazard. (b) On or about November 22, 2017, at a workplace located at 1321 Commerce Street, Dallas, TX 75202, employees working in the vicinity of a Humphrey belt man lift, serial number S-4006, model number 14S GHC-3-RA, where a gate or rail was not provided were exposed to a fall hazard.
Recent events (2)
- — I (O) $3900
- — Z (S) $11641
1910.68 B12
- Issued
- Feb 23, 2018
- Abate by
- Mar 21, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.68(b)(12): Emergency exit ladder. A fixed metal ladder accessible from the "up" and "down" run of the man lift was not provided for the entire travel of the man lift: (a) On or about November 22, 2017, at a workplace located at 1321 Commerce Street, Dallas, TX 75202, employees using a Humphrey belt man lift, serial number S-4006, model number 14S GHC-3-RA, with no emergency exit ladder to be used in case of malfunction were exposed to a fall hazard to the lower level.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B01 I
- Issued
- Feb 23, 2018
- Abate by
- Mar 21, 2018
- Penalty
- Initial $11,641 · Current $0 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings were not protected from abrasion, and openings through which conductors enter were not effectively closed: (a) On or about November 22, 2017, at a workplace located at 1321 Commerce Street, Dallas, TX 75202, employees using a Humphrey belt man lift, serial number S-4006, model number 14S GHC-3-RA, with a missing knock out at the motor shaft, were exposed an electrical hazard; (b) On or about November 22, 2017, at a workplace located at 1321 Commerce Street, Dallas, TX 75202, employees working in the vicinity of a Humphrey belt man lift, serial number S-4006, model number 14S GHC-3-RA, with a missing knock out at the motor shaft, were exposed to an electrical hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $11641
1910.305 G02 III
- Issued
- Feb 23, 2018
- Abate by
- Mar 21, 2018
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws: (a) On or about November 22, 2017, at a workplace located at 1321 Commerce Street, Dallas, TX 75202, employees using a Humphrey belt man lift, serial number S-4006, model number 14S GHC-3-RA, that had a junction box with a missing strain relief were exposed to an electrical hazard; (b) On or about November 22, 2017, at a workplace located at 1321 Commerce Street, Dallas, TX 75202, employees working in the vicinity of a Humphrey belt man lift, serial number S-4006, model number 14S GHC-3-RA, that had a junction box with a missing strain relief were exposed to an electrical hazard.