OSHA Inspection: SPECIALTY ROLLED METALS LLC

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of SPECIALTY ROLLED METALS LLC in 112 MARY ANN ROAD, BEAVER DAM, WI 53916 (NAICS 332813). OSHA activity number 342794799.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Specialty Rolled Metals LLC — free Get an email when a new federal OSHA severe-injury report for Specialty Rolled Metals LLC is published. One employer, no account, unsubscribe in one click.
Site address
112 MARY ANN ROAD
City
BEAVER DAM
State
WI
ZIP
53916
Mailing
112 MARY ANN ROAD, BEAVER DAM, WI 53916
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332813
Employees
28
Ownership type
A

5 citations on file for this inspection.

5(a)(1)

Deleted Serious Gravity 10 2 instances 28 exposed
Issued
Apr 27, 2018
Abate by
May 18, 2018
Penalty
Initial $9,054 · Current $0 Reduced
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that caused or were likely to cause death or serious physical harm in that employees were exposed to fire and explosion hazards form hydrogen gas.  On or about November 28, 2017, employees operating annealing Furnace #2 and Furnace #3 were exposed to fire and explosion hazards due to hydrogen gas emitting from the open exit end of both furnaces.  Among other methods, on feasible and acceptable method to correct this hazard includes, but is not limited to, include to follow the National Fire Protection Association  NFPA 86  Standard for Ovens and Furnaces, 2015 Edition, Chapter 13.5.11.2 requiring a burn-off pilot, glow plug, flame screen or other source of ignition to be provided and located at the gas-air interface and sized to reliably ignite the flammable special atmosphere gas that is released at open ends.
Recent events (3)
  • — F (S) $0
  • — C (S) $9054
  • — Z (S) $9054

1910.178 C02 IV

Deleted Serious Gravity 10 2 instances 28 exposed
Issued
Apr 27, 2018
Abate by
May 18, 2018
Penalty
Initial $9,054 · Current $0 Reduced
29 CFR 1910.178(c)(2)(iv): Power-operated industrial trucks designated as DY, EE, or EX were not used in locations where volatile flammable liquids or flammable gases are handled, processed or used, but in which the hazardous liquids, vapors or gases will normally be confined within closed containers or closed systems from which they can escape only in case of accidental rupture or breakdown of such containers or systems, or in the case of abnormal operation of equipment; also in locations in which hazardous concentrations of gases or vapors are normally prevented by positive mechanical ventilation but which might become hazardous through failure or abnormal operation of the ventilating equipment; or in locations which are adjacent to Class I, Division 1 locations, and to which hazardous concentrations of gases or vapors might occasionally be communicated unless such communication is prevented by adequate positive-pressure ventilation from a source of clear air, and effective safeguards against ventilation failure are provided.  On November 28, 2018, the employer did not ensure that the powered industrial trucks used near and around the annealing furnaces were designated as DY, EE or EX in the event that hydrogen gas from the furnaces would escape  under abnormal conditions and reach hazardous concentrations.
Recent events (3)
  • — F (S) $0
  • — C (S) $9054
  • — Z (S) $9054

1910.307 C

Serious Gravity 10 2 instances 28 exposed
Issued
Apr 27, 2018
Abate by
Dec 6, 2019
Penalty
Initial $9,054 · Current $4,527 Reduced
29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location.    On or about November 28, 2017, equipment and installations of equipment in the areas around the annealing furnaces, a Class 1, Division 1 and 2 locations, were not intrinsically safe, approved for the hazardous locations, or safe for the hazardous locations.    a) Propane forklifts were used in the areas around the annealing furnaces that were not rated for Class 1, Division 1 and 2 locations.    b) Standard electrical outlets, fluorescent lighting, open vented electrical cabinets, electrical transformers and motors were used in areas around the annealing furnaces that were not rated for Class 1, Division 1 and 2 locations.
Recent events (3)
  • — F (S) $4527
  • — C (S) $9054
  • — Z (S) $9054

1910.1200 H02 II

Serious Gravity 10 1 instance 28 exposed
Issued
Apr 27, 2018
Abate by
May 6, 2019
Penalty
Initial $9,054 · Current $4,527 Reduced
29 CFR 1910.1200(h)(2)(ii): Any operations in their work area where hazardous chemicals are present; and,    On or about November 28, 2018, the employer did not train the furnace operators on the hazards of hydrogen gas and nitrogen gas, as fire/explosion hazards and asphyxiation hazards, respectively.
Recent events (3)
  • — F (S) $4527
  • — C (S) $9054
  • — Z (S) $9054

1904.41 A02

Other-than-serious 1 instance 28 exposed
Issued
Apr 27, 2018
Abate by
May 6, 2019
Penalty
Initial $0 · Current $0
29 CFR 1904.41(a)(2): The establishment had 20 or more employees but fewer than 250 employees at any time during the previous calendar year, and the establishment is classified in an industry listed in appendix A to subpart E of this part, but did not electronically submit information from OSHA Form 300A Summary of Work-Related Injuries and Illnesses to OSHA or OSHA's designee. You must submit the information once a year, no later than the date listed in paragraph (c) of this section of the year after the calendar year covered by the form.    On or about December 15, 2017, the employer failed to submit their 300A Summary of Work-Related Injuries and Illnesses to OSHA for calendar year 2016.
Recent events (3)
  • — F (O) $0
  • — C (O) $0
  • — Z (O) $0

View Specialty Rolled Metals LLC's full OSHA safety record →